Worked example

12-Inch Shallow Reef PAR Loss through a Glass Lid

A shallow reef measures 280 PAR above the lid. Salt deposits and condensation are estimated to remove 15% at the lid, with another 3% at the air-water interface.

See the worked calculation

Inputs

View results
Light and water column
µmol/m²/s

Use an appropriate quantum meter near the center of the intended zone.

in
%
%
PAR just below the surface
230.86 µmol/m²/s
PAR at selected depth
201.3 µmol/m²/s
Placement reference band
Moderate reef light
Underwater PAR attenuationThe estimated reading falls from 230.9 at the surface to 201.3 at 12 in. Depth below the surface0 in03 in636 in1259 in18812 in250µmol/m²/s (PAR)201.3 at depth
PAR from surface to substrate

Calculation details

Input PAR reaching that depth
71.9 %
PAR halfway down
215.56 µmol/m²/s
Effective attenuation
0.45 m⁻¹
  • Check PAR at actual placements. Rock shadows, LED optics and surface motion can change the reading.

Input measurements

Surface PAR reading
280 µmol/m²/s
Where PAR was measured
Above lid and water
Depth below the surface
12 in
Water clarity or calibration
Clear · 0.45 m⁻¹
Lid transmission loss
15 %
Air-to-water reflection loss
3 %
Placement reference bands
Coral reef

Check PAR at several actual placements with an underwater quantum meter. Acclimate coral and plants to light changes, and track water quality with the appropriate test kits.

Worked calculation

These numbers use the original example measurements. The calculator above updates as you edit.

  1. Find PAR just under the surface

    280 × (1 − 0.15) × (1 − 0.03) = 230.86 µmol/m²/s

    The lid and air–water interface reduce the above-water reading in sequence.

  2. Evaluate the attenuation curve

    230.86 × exp(−0.45 × 0.3048) = 201.27 µmol/m²/s

    At 12 in, the estimate is in the moderate reef light band. Halfway down it is 215.56 µmol/m²/s.

Frequently asked questions

Are 15% lid loss and 3% reflection added as 18%?

They act in sequence. Multiply 0.85 by 0.97 for 82.45% transmission, or 17.55% combined loss.

Can a glass lid cleaning raise a shallow reef’s PAR quickly?

It can if deposits blocked part of the beam. Take measurements at coral height before and after a major change.