- Estimated dissolved CO₂
- 30.1 ppm
- CO₂ planning classification
- Elevated
- KNO₃ per macro dose
- 1.728 g
Calculation details
- KH₂PO₄ per macro dose
- 0.217 g
- K₂SO₄ per macro dose
- 1.071 g
- Potassium from N and P salts
- 4.83 ppm
- Delivered potassium per dose
- 8 ppm
- Weekly nitrate added before uptake
- 21 ppm
- KNO₃ per week
- 5.185 g
- KH₂PO₄ per week
- 0.651 g
- K₂SO₄ per week
- 3.213 g
- CO₂ is above the green planning band. Check the reading and observe livestock respiration before further injection.
- The estimate assumes carbonate buffering. Verify with pH and KH tests and a 4 dKH reference drop checker.
Input measurements
- Measured pH
- 6.6
- Measured carbonate hardness
- 4 dKH
- Net water volume
- 40 US gal
- Nitrate per dose as NO₃
- 7 ppm
- Phosphate per dose as PO₄
- 1 ppm
- Potassium target per dose as K
- 8 ppm
- Macro doses per week
- 3
Verify pH, KH and nutrient readings with suitable test kits. Start low, observe fish and shrimp, and increase aeration if livestock show respiratory distress.
How the calculation works
CO₂ in ppm is estimated as 3 × KH × 10^(7 − pH), with KH in dKH. The formula assumes carbonate buffering dominates. Active soil, tannins and non-carbonate buffers can move pH without changing CO₂. Compare the estimate with a dedicated drop checker that uses its own 4 dKH reference solution. A checker responds with a delay.
The heatmap uses 15–30 ppm as an illustrative green planning band. Its boundaries do not establish what a particular fish or shrimp can tolerate. Check pH and KH, watch respiration and provide surface gas exchange.
Dry EI dose mass comes from target ion mg/L, actual water volume and the ion mass fraction of each salt. Subtract potassium supplied by KNO₃ and KH₂PO₄ before calculating a K₂SO₄ top-up. Weekly figures are additions before uptake and water changes.
References
Frequently asked questions
Why can a drop checker and the tank pH/KH chart disagree?
A drop checker uses a separate solution with known carbonate hardness and responds over time. Tank acid buffers can change pH, while device placement and the checker’s lag can explain timing differences.
Why does the EI calculator sometimes show zero potassium sulfate?