- Design ESALs
- 7.31M
ESAL
- Lane trucks
- 828.2
trucks/day
- Growth sum
- 12.724
- Truck factor
- 1.9
Design-lane traffic funnel
Bars show traffic allocation or relative axle-group contributions. The fourth-power option is a screening approximation.
Design-lane allocation
Marker shows the share of two-way heavy trucks assigned to the design lane.
Calculation ledger
- Opening-year design ESALs
- 574,384 ESAL
- Cumulative design-lane trucks
- 3,846,613
- Two-way truck share in design lane
- 49.3%
- Single-group factor
- —
- Tandem-group factor
- —
- Tridem-group factor
- —
Work through this example
- Apply truck share, direction and lane allocation to opening two-way traffic.
- Compound opening-year traffic across the design period.
- Multiply cumulative trucks by the selected ESALs per truck.
The growth multiplier should be less than 15. Compare with a flat forecast.
Use an agency truck factor or a measured axle spectrum for final design. The grouped fourth-power factors use nominal group reference loads.
Read the equations and sources
Design-lane allocation. Marker shows the share of two-way heavy trucks assigned to the design lane.
Inputs
| Initial two-way AADT | 6,000 veh/day |
|---|
| Heavy trucks | 28% |
|---|
| Direction factor Dᴅ | 58% |
|---|
| Lane factor Dʟ | 85% |
|---|
| Annual growth g | -2.4% |
|---|
| Design period n | 15 yr |
|---|
| Truck factor method | Entered truck factor |
|---|
| ESALs per truck | 1.9 |
|---|
| Single groups per truck | 1 |
|---|
| Single group load | 14 kip |
|---|
| Tandem groups per truck | 2 |
|---|
| Tandem group load | 32 kip |
|---|
| Tridem groups per truck | 0 |
|---|
| Tridem group load | 44 kip |
|---|
Results
| Cumulative design ESALs | 7,308,564 ESAL |
|---|
| Opening design-lane trucks | 828.2 trucks/day |
|---|
| Growth multiplier | 12.724 |
|---|
| Truck equivalency | 1.9 |
|---|
| Opening-year design ESALs | 574,384 ESAL |
|---|
| Cumulative design-lane trucks | 3,846,613 |
|---|
| Two-way truck share in design lane | 49.3% |
|---|
| Single-group factor | — |
|---|
| Tandem-group factor | — |
|---|
| Tridem-group factor | — |
|---|
Use an agency truck factor or a measured axle spectrum for final design. The grouped fourth-power factors use nominal group reference loads.