- Design ESALs
- 27.82M
ESAL
- Lane trucks
- 1,133.7
trucks/day
- Growth sum
- 25.545
- Truck factor
- 2.632
Design-lane traffic funnel
Bars show traffic allocation or relative axle-group contributions. The fourth-power option is a screening approximation.
Design-lane allocation
Marker shows the share of two-way heavy trucks assigned to the design lane.
Calculation ledger
- Opening-year design ESALs
- 1,089,023 ESAL
- Cumulative design-lane trucks
- 10,570,276
- Two-way truck share in design lane
- 46.75%
- Single-group factor
- 0.1975
- Tandem-group factor
- 1.2569
- Tridem-group factor
- 1.1774
Work through this example
- Apply truck share, direction and lane allocation to opening two-way traffic.
- Compound opening-year traffic across the design period.
- Multiply cumulative trucks by the selected ESALs per truck.
The ledger reports each group factor. Change only the tridem load and observe the total truck factor.
Use an agency truck factor or a measured axle spectrum for final design. The grouped fourth-power factors use nominal group reference loads.
Read the equations and sources
Design-lane allocation. Marker shows the share of two-way heavy trucks assigned to the design lane.
Inputs
| Initial two-way AADT | 9,700 veh/day |
|---|
| Heavy trucks | 25% |
|---|
| Direction factor Dᴅ | 55% |
|---|
| Lane factor Dʟ | 85% |
|---|
| Annual growth g | 2.5% |
|---|
| Design period n | 20 yr |
|---|
| Truck factor method | Fourth-power axle groups |
|---|
| ESALs per truck | 1.35 |
|---|
| Single groups per truck | 1 |
|---|
| Single group load | 12 kip |
|---|
| Tandem groups per truck | 1 |
|---|
| Tandem group load | 36 kip |
|---|
| Tridem groups per truck | 1 |
|---|
| Tridem group load | 50 kip |
|---|
Results
| Cumulative design ESALs | 27,818,725 ESAL |
|---|
| Opening design-lane trucks | 1,133.7 trucks/day |
|---|
| Growth multiplier | 25.545 |
|---|
| Truck equivalency | 2.632 |
|---|
| Opening-year design ESALs | 1,089,023 ESAL |
|---|
| Cumulative design-lane trucks | 10,570,276 |
|---|
| Two-way truck share in design lane | 46.75% |
|---|
| Single-group factor | 0.1975 |
|---|
| Tandem-group factor | 1.2569 |
|---|
| Tridem-group factor | 1.1774 |
|---|
Use an agency truck factor or a measured axle spectrum for final design. The grouped fourth-power factors use nominal group reference loads.