- Design ESALs
- 1.96M
ESAL
- Lane trucks
- 210
trucks/day
- Growth sum
- 25.545
- Truck factor
- 1
Design-lane traffic funnel
Bars show traffic allocation or relative axle-group contributions. The fourth-power option is a screening approximation.
Design-lane allocation
Marker shows the share of two-way heavy trucks assigned to the design lane.
Calculation ledger
- Opening-year design ESALs
- 76,650 ESAL
- Cumulative design-lane trucks
- 1,957,998
- Two-way truck share in design lane
- 50%
- Single-group factor
- 1
- Tandem-group factor
- 0.7847
- Tridem-group factor
- 0.7061
Work through this example
- Apply truck share, direction and lane allocation to opening two-way traffic.
- Compound opening-year traffic across the design period.
- Multiply cumulative trucks by the selected ESALs per truck.
The truck factor is exactly 1. Raise the single load by 10% to see the fourth-power response.
Use an agency truck factor or a measured axle spectrum for final design. The grouped fourth-power factors use nominal group reference loads.
Read the equations and sources
Design-lane allocation. Marker shows the share of two-way heavy trucks assigned to the design lane.
Inputs
| Initial two-way AADT | 4,200 veh/day |
|---|
| Heavy trucks | 10% |
|---|
| Direction factor Dᴅ | 50% |
|---|
| Lane factor Dʟ | 100% |
|---|
| Annual growth g | 2.5% |
|---|
| Design period n | 20 yr |
|---|
| Truck factor method | Fourth-power axle groups |
|---|
| ESALs per truck | 1.35 |
|---|
| Single groups per truck | 1 |
|---|
| Single group load | 18 kip |
|---|
| Tandem groups per truck | 0 |
|---|
| Tandem group load | 32 kip |
|---|
| Tridem groups per truck | 0 |
|---|
| Tridem group load | 44 kip |
|---|
Results
| Cumulative design ESALs | 1,957,998 ESAL |
|---|
| Opening design-lane trucks | 210 trucks/day |
|---|
| Growth multiplier | 25.545 |
|---|
| Truck equivalency | 1 |
|---|
| Opening-year design ESALs | 76,650 ESAL |
|---|
| Cumulative design-lane trucks | 1,957,998 |
|---|
| Two-way truck share in design lane | 50% |
|---|
| Single-group factor | 1 |
|---|
| Tandem-group factor | 0.7847 |
|---|
| Tridem-group factor | 0.7061 |
|---|
Use an agency truck factor or a measured axle spectrum for final design. The grouped fourth-power factors use nominal group reference loads.