Subgrade CBR & Frost Penetration

Screen subgrade stiffness from soaked CBR, estimate composite reaction k, and compare homogeneous frost penetration with frost-resistant pavement depth.

Design readout

Powell Mᵣ
8,042.8
psi
Support k
447.9
pci
Frost depth
28.76
in
Depth margin
-6.76
in

Frost penetration profile

Frost penetration profileTHERMAL PROFILEDEPTH BELOW SURFACERESISTANT DEPTH22 inFROST FRONT28.76 inSURFACE INDEX476 °F·daysBARE K414.6 pciCOMPOSITE K447.9 pci
Both depths are measured from the surface. The frost model uses one equivalent thermal material.

Frost reaches below section

Subbase modulus is outside the FHWA guidance of 15–50 ksi and less than 4 × roadbed modulus. Marker shows resistant depth relative to modeled frost depth.

Calculation ledger
Linear CBR modulus E
9,000 psi
Bare subgrade k from Powell modulus
414.58 pci
Uncorrected Stefan depth
36.88 in
Surface freezing index
476 °F·days

Inputs

Changes update results

Subgrade and pavement
%
%
lb/ft³
in
in
ksi
Thermal assumptions
°F·days
Btu/(h·ft·°F)

Set λ to 1 for the Stefan result. Calibrate the thermal inputs using local data.

How the calculation works

  1. Compare two CBR-to-modulus correlations for the soaked soil.
  2. Use Powell Mᵣ with granular subbase thickness and stiffness to estimate composite k.
  3. Compute frost depth from the surface freezing index, conductivity and soil water, then compare with the resistant section.

The linear CBR correlation is a low-CBR fine-soil screen. Composite k uses the FHWA chart range for thickness and roadbed stiffness and omits seasonal, erosion and bedrock corrections. Use measured support and a layered thermal analysis where warranted.

Read the equations and sources