Both depths are measured from the surface. The frost model uses one equivalent thermal material.
Review composite support
Subbase modulus is outside the FHWA guidance of 15–50 ksi and less than 4 × roadbed modulus. Marker shows resistant depth relative to modeled frost depth.
Calculation ledger
Linear CBR modulus E
12,000 psi
Bare subgrade k from Powell modulus
498.39 pci
Uncorrected Stefan depth
26.12 in
Surface freezing index
364 °F·days
Inputs
Changes update results
Work through this example
Compare two CBR-to-modulus correlations for the soaked soil.
Use Powell Mᵣ with granular subbase thickness and stiffness to estimate composite k.
Compute frost depth from the surface freezing index, conductivity and soil water, then compare with the resistant section.
Reduce the resistant depth until the frost margin crosses zero.
The linear CBR correlation is a low-CBR fine-soil screen. Composite k uses the FHWA chart range for thickness and roadbed stiffness and omits seasonal, erosion and bedrock corrections. Use measured support and a layered thermal analysis where warranted.
Subgrade CBR & Frost Penetration · US customary units
Review composite support. Subbase modulus is outside the FHWA guidance of 15–50 ksi and less than 4 × roadbed modulus. Marker shows resistant depth relative to modeled frost depth.
Inputs
Soaked CBR
8%
Gravimetric moisture w
16%
Dry density γᵈ
112 lb/ft³
Frost-resistant section Hₚₐᵥ
46 in
Rigid granular subbase depth
12 in
Granular subbase modulus
40 ksi
Air freezing index
520 °F·days
Mean thermal conductivity
0.7 Btu/(h·ft·°F)
Air-to-surface factor n
0.7
Berggren correction λ
0.78
Results
Powell resilient modulus
9,668.7 psi
Estimated composite reaction
630.7 pci
Modified Berggren depth
20.38 in
Frost-resistant depth margin
25.62 in
Linear CBR modulus E
12,000 psi
Bare subgrade k from Powell modulus
498.39 pci
Uncorrected Stefan depth
26.12 in
Surface freezing index
364 °F·days