Both depths are measured from the surface. The frost model uses one equivalent thermal material.
Frost reaches below section
Subbase modulus is outside the FHWA guidance of 15–50 ksi and less than 4 × roadbed modulus. Marker shows resistant depth relative to modeled frost depth.
Calculation ledger
Linear CBR modulus E
9,000 psi
Bare subgrade k from Powell modulus
414.58 pci
Uncorrected Stefan depth
41.68 in
Surface freezing index
608 °F·days
Inputs
Changes update results
Work through this example
Compare two CBR-to-modulus correlations for the soaked soil.
Use Powell Mᵣ with granular subbase thickness and stiffness to estimate composite k.
Compute frost depth from the surface freezing index, conductivity and soil water, then compare with the resistant section.
The corrected and uncorrected depths coincide. Change λ to 0.8 and check the proportional reduction.
The linear CBR correlation is a low-CBR fine-soil screen. Composite k uses the FHWA chart range for thickness and roadbed stiffness and omits seasonal, erosion and bedrock corrections. Use measured support and a layered thermal analysis where warranted.
Subgrade CBR & Frost Penetration · US customary units
Frost reaches below section. Subbase modulus is outside the FHWA guidance of 15–50 ksi and less than 4 × roadbed modulus. Marker shows resistant depth relative to modeled frost depth.
Inputs
Soaked CBR
6%
Gravimetric moisture w
12%
Dry density γᵈ
112 lb/ft³
Frost-resistant section Hₚₐᵥ
35 in
Rigid granular subbase depth
8 in
Granular subbase modulus
40 ksi
Air freezing index
760 °F·days
Mean thermal conductivity
0.8 Btu/(h·ft·°F)
Air-to-surface factor n
0.8
Berggren correction λ
1
Results
Powell resilient modulus
8,042.8 psi
Estimated composite reaction
481 pci
Modified Berggren depth
41.68 in
Frost-resistant depth margin
-6.68 in
Linear CBR modulus E
9,000 psi
Bare subgrade k from Powell modulus
414.58 pci
Uncorrected Stefan depth
41.68 in
Surface freezing index
608 °F·days
The linear CBR correlation is a low-CBR fine-soil screen. Composite k uses the FHWA chart range for thickness and roadbed stiffness and omits seasonal, erosion and bedrock corrections. Use measured support and a layered thermal analysis where warranted.