Worked example · Energy
208 V, 32 A vs 240 V Level 2 Charging
Time a 25–85% refill of a 60 kWh pack on a 208 V garage supply and compare the result with 240 V.
Setup
Results
Runs in your browserSetup
- Distance per year
- 12000 mi
- EV battery energy use
- 28 kWh/100 mi
- Electricity price
- 0.16 $/kWh
- Gasoline price
- 3.6 $/US gal
- Gas vehicle economy
- 28 mpg US
- Hybrid vehicle economy
- 48 mpg US
- Usable battery capacity
- 60 kWh
- Starting charge
- 25 %
- Target charge
- 85 %
- AC wall-to-pack efficiency
- 88 %
- Level 1 current at 120 V
- 12 A
- Level 2 line voltage
- 208 V
- Level 2 charging current
- 32 A
- Vehicle AC input limit
- 7.2 kW
- DC session-average power
- 110 kW
- DC connector-to-pack efficiency
- 95 %
- Annual EV energy cost
- $610.91
- 3,818 kWh from wall
- Annual gas energy cost
- $1,542.86
- Hybrid $900
- Five-year EV savings vs gas
- $4,659.74
- Vs hybrid $1,445.45
- Level 2 recharge time
- 6.15 h
- 36 kWh into battery
| Vehicle | Per year | Per 100 mi | Annual energy |
|---|---|---|---|
| EV | $610.91 | $5.09 | 3,818 kWh |
| Gas | $1,542.86 | $12.86 | 429 US gal |
| Hybrid | $900 | $7.5 | 250 US gal |
| Type | Input power | Metered energy | Time |
|---|---|---|---|
| Level 1 | 1.44 kW | 40.91 kWh | 28.41 h |
| Level 2 | 6.66 kW | 40.91 kWh | 6.15 h |
| DC fast | 110 kW | 37.89 kWh | 0.34 h |
This compares energy only and assumes the entered wall-to-pack efficiency and local rates. Tariffs, temperature, usable capacity and charge taper affect real costs and times. Enter equipment current available to the vehicle and use the vehicle’s charging specifications.
Spec sheet
Worked math for the starting setup
Find available power at 208 V
208 × 32 ÷ 1,000 = 6.656 kW. That is below the 7.2 kW vehicle limit.
Estimate the time difference
60 × 0.60 ÷ 0.88 = 40.91 kWh from the wall. At 208 V it takes 6.15 hours. At 240 V and the 7.2 kW limit it takes about 5.68 hours.
Enter the operating voltage and current available to the car. A commercial garage may supply 208 V where a home setup supplies 240 V.
Common questions
How much less power is available at 208 V than at 240 V with the same 32 A current?
The supply powers are 6.656 and 7.68 kW. The vehicle limit in this example also caps the 240 V side at 7.2 kW.
Is a 208 V Level 2 charger still Level 2 at this 32 A setting?
Yes. Level 2 AC installations can use 208 V or 240 V. Enter the actual equipment voltage for the time estimate.