The calculations combine first-principles geometry and mass balances with documented empirical correlations. The settings on each tool expose the quantities and assumptions you can substitute.
Unit and mass conventions
US TPH means short tons per hour. SI t/h means metric tonnes per hour. A short ton is 2,000 pounds, or exactly 0.90718474 metric tonnes. GPM uses the US liquid gallon. HP is mechanical horsepower, approximately 0.7457 kW. Slopes stored as rise/run are displayed in inches per foot in US and degrees in SI.
Inputs are stored in one canonical basis. Switching units only changes their display. Bond work index and specific energy convert with the mass basis, so calculated power is the same. Conveyor belt widths in inches and nominal millimetre sizes are approximate trade equivalents.
Three equal-roll trough geometry, with center roll width c = B/3 and usable belt width 0.9B − 2 in. The loaded wings have horizontal projection a and rise h. Surcharge θ is the edge tangent angle of a circular cap, with R = (c + 2a)/(2 sin θ). The cap vanishes at 0°. Match the actual idlers, edge clearance and loading condition for detailed work.
D is flight OD, d is shaft OD, p is flight pitch, N is rpm, and f is 15%, 30% or 45% loading. In metres this gives m³/h. The default retained fraction k is interpolated through 100%, 95%, 75%, 60% and 35% at 0°, 10°, 20°, 30° and 45°. These are illustrative values. Pitch, housing, fallback and material tests can change the derate.
Bucket fill f and pitch p describe one row of buckets. The rate assumes steady full-width feeding at the specified bucket loading. Belt or chain pitch speed and head diameter must use consistent units.
R and r are base and top radii. The cone has r = 0. The input repose angle is measured up from horizontal. Measure its actual slope where the pile profile or material varies.
The default C₀ is 2.2 × aperture(in)^0.55 short tons/h/ft². Reference conditions are 25% oversize, 40% half-size, 100 lb/ft³, top deck, dry screening and 90% recovery. Fo = 1 + 0.5(oversize fraction − 0.25), Fh = 1 + (half-size fraction − 0.40), and Fd = 1/0.9/0.8 by deck position (top/second/third respectively). Wet spray uses Fw = 1 + 0.3/(1 + aperture(in)²). Fρ scales with bulk density. The curve and corrections are illustrative VSMA-style estimates. Use an OEM rating and validate motion, media open area, bed depth and blinding before selection.
F80 and P80 are the sizes through which 80% of the feed and product mass pass. Reduction ratio uses equal size units. The Bond equation converts both to micrometres.
Cw and Cv are fractions on mass and volume bases. Ss is solids SG and SL is carrier SG, both relative to water. The mixture relation assumes additive phase volumes.
L and D may both be metres or both be feet. N is rpm, S is rise over horizontal run, and t is minutes. This handbook form uses a fixed 0.19 coefficient. The entered repose angle sets the drawn bed orientation. Material-specific residence time depends on repose, flights, dams, conveying action and gas flow.