CEMA-style screw power

Screw Conveyor Capacity & Torque Calculator

Calculate auger CFH, mass throughput, incline loss, drive power and shaft torque for a control-fed, shafted screw.

Live results

Auger flight, pitch and loaded annulus

Edit inputs
Auger flight, pitch and loaded annulus Four live readings and a schematic of the selected material-handling configuration. Full values follow the diagram. VOLUME RATE927.75CFHMASS RATE32.47TPHSHAFT TORQUE2552.88lb-inMOTOR POWER3.22HP AUGER FLIGHTTROUGH SECTIONFlowPitch 12 in0° inclineFlight OD 12 in30% effective fill Incline capacity retained100%Compared with the same screw operating horizontally.

Compared with the same screw operating horizontally.

All calculated values
Volume throughput
927.752CFH
Mass throughput
32.471TPH
Screw shaft torque
2,552.878lb-in
Motor power
3.222HP
Open flight annulus
0.736ft²
Incline capacity retained
100%
Effective fill after derate
30%
Diameter factor
55
Empty screw power
0.108HP
Material power before multiplier
2.728HP
Vertical rise
0ft
Gravity lift power
0HP
Screw shaft power
2.835HP

Inputs

Unit system
Operating inputs
in
in
in
RPM
°
ft
lb/ft³
Drive & model factors
%
0 applies the angle-based estimate. Enter a measured percentage to override it.
Enter an OEM overload or fallback allowance if known.
%

Worked examples

Open and edit any starting case

Equations and assumptions

Annular displacement and incline

Qᵥ = (π/4)(D² − d²) · p · N · 60 · f · k

D is flight OD, d is shaft OD, p is flight pitch, N is rpm, and f is 15%, 30% or 45% loading. In metres this gives m³/h. The default retained fraction k is interpolated through 100%, 95%, 75%, 60% and 35% at 0°, 10°, 20°, 30° and 45°. These are illustrative values. Pitch, housing, fallback and material tests can change the derate.

Empty and material horsepower

HPf = Fd Fb L N / 10⁶   |   HPm = ṁ Fm L / 10⁶

The KWS control-fed convention uses L in feet, ṁ in lb/h and empirical diameter, hanger and material factors. Diameter factor is interpolated through the published screw diameters. The optional multiplier applies to material power. Obtain OEM correction for low material HP, startup and flood feeding.

Gravity, motor and shaft torque

Plift = ṁ g L sin α   |   Pshaft = Pf + multiplier · Pm + Plift
Pmotor = Pshaft/η   |   τ = Pshaft/(2πN/60)

Use kg/s for ṁ and watts for the SI torque equation. Torque is at the screw shaft, after the drive losses used to estimate motor size.

References