Worked example · Product cooling

Freezing a batch of berries

A batch of berries leaves pre-cooling and passes through its freezing plateau before reaching the frozen-storage target.

Pull-down time
1.61h
Heat removed
139,729kJ
Effective rate
24.12kW
Freeze time
1.35h
Edit inputs

Inputs

Edit any value to recalculate.

Batch & temperatures
kg
°C
°C
°C
Product properties
kJ/(kg·K)
kJ/(kg·K)
kJ/kg
Equipment

Enter refrigeration output at the actual operating condition. The percentage is the share available to remove product heat.

kW
%

Core temperature pull-down

Core temperature pull-downA constant effective capacity turns each sensible or latent heat term into the length of its stage.Core temperature / °CElapsed time / h00.40.81.31.7-19.6-10.5-1.57.6Above freezePhase changeBelow freeze

A constant effective capacity turns each sensible or latent heat term into the length of its stage.

Calculation breakdown

Sensible heat above freezing
9,416kJ
Heat of fusion
117,600kJ
Sensible heat below freezing
12,713kJ
Heat per unit mass
332.69kJ/kg
Time above freezing
0.11h
Time below freezing
0.15h

Work through this case

  1. Heat of fusion 117,600kJ
  2. Freeze time 1.35h
  3. Pull-down time 1.61h

Inspect how much time is assigned to fusion. Tray packing and airflow can change effective capacity at the same equipment rating.

More worked examples

Open a case with its assumptions loaded, then edit the inputs.

Open base calculator

Formulas and assumptions

Three-stage batch enthalpy

Etotal = m × c₊ΔT₊ + m × Lf + m × c₋ΔT₋

The sensible terms use temperature changes above and below the freezing point. A batch starting below freezing uses only the last term. A batch stopping at the freezing point ends before the latent stage in this model.

Estimated core pull-down

t = Etotal / (3,600 × Qrated × effectiveness)

For E in kJ and Q in kW the answer is hours. Pack geometry, access to air, and surface/core gradients are folded into one estimated effectiveness. Validate core temperatures with probes under the intended loading.

References

Questions and answers

What should I check in the freezing a batch of berries example?

Inspect how much time is assigned to fusion. Tray packing and airflow can change effective capacity at the same equipment rating.