The sensible terms use temperature changes above and below the freezing point. A batch starting below freezing uses only the last term. A batch stopping at the freezing point ends before the latent stage in this model.
Estimated core pull-down
t = Etotal / (3,600 × Qrated × effectiveness)
For E in kJ and Q in kW the answer is hours. Pack geometry, access to air, and surface/core gradients are folded into one estimated effectiveness. Validate core temperatures with probes under the intended loading.
What should I check in the freezing a pastry dough batch example?
Try two measured or plausible effectiveness values to see how uncertainty in air access shifts the projected pull-down time.
ColdChainLab · Engineering calculation
Freezing a pastry dough batch
Metric SI · https://calcsheetlab.com/coldchainlab/blast-chiller-freezing-time/pastry-dough-batch-freeze/
Inputs
Batch mass
210 kg
Initial core temperature
18 °C
Target core temperature
-19 °C
Product freeze point
-3.2 °C
Specific heat above freezing
2.7 kJ/(kg·K)
Specific heat below freezing
1.52 kJ/(kg·K)
Latent heat of fusion
150 kJ/kg
Rated refrigeration capacity
21 kW
Effective batch capacity
47 %
Results
Pull-down time
1.37h
Heat removed
48,564kJ
Effective rate
9.87kW
Freeze time
0.89h
Sensible heat above freezing
12,020kJ
Heat of fusion
31,500kJ
Sensible heat below freezing
5,043kJ
Heat per unit mass
231.26kJ/kg
Time above freezing
0.34h
Time below freezing
0.14h
Use these estimates for preliminary engineering. Verify results against validated cold-chain qualification protocols, applicable ASHRAE Standards 15 and 34, and local food and pharmaceutical regulations. Use manufacturer data, measured operating conditions, and approved acceptance criteria before acting on a result.