Worked example

Cross-ply glass bending strip

Apply a pure longitudinal moment to a glass/epoxy cross-ply strip.

With symmetric stacking, mid-plane strains are zero for this pure moment. Compare Ex,f and Ey,f to see the influence of outer plies.

View live results

Inputs

Ply material
GPa
GPa
GPa
g/cm³
Ply stack

Enter blocks from the bottom face to the top face.

1
2
3
4
5
6
7
8
Membrane loads
N/mm
N/mm
N/mm
Moments per unit width
N
N
N

Live results

SI
Thickness
1 mm
Membrane Ex
28.689 GPa
Bending Ex,f
34.895 GPa
Areal mass
1,950 g/m²
No extension–bending couplingMirrored stacking sequence
Laminate edge section
Scaled laminate stack and thickness-weighted fiber orientation composition +z / TOP−z / BASE1 mm0°50%±45°0%90°50%Other0%
  • 0°
  • ±45°
  • 90°
  • Other
0° fiber thickness share50%
0%100% of stack

Engineering constants

Membrane Ey
28.6894 GPa
Membrane Gxy
4.5 GPa
Membrane νxy
0.113684
Bending Ey,f
22.4462 GPa
Ply count
8
max |Bᵢⱼ|
0 N

Mid-plane response

ε⁰ x
0 µε
ε⁰ y
0 µε
ε⁰ xy
0 µε
κ x
0.00275108 mm⁻¹
κ y
−3.99485e-4 mm⁻¹
κ xy
0 mm⁻¹

ABD stiffness A N/mm · B N · D N·mm

εxεyγxyκxκyκxy
Nx29,0703,3040000
Ny3,30429,0700000
Nxy004,500000
Mx0002,948275.40
My000275.41,8960
Mxy00000375

Model and assumptions

A = ΣQ̄ Δz · B = ½ΣQ̄ Δ(z²) · D = ⅓ΣQ̄ Δ(z³) · [N; M] = [A B; B D][ε⁰; κ].

Enter blocks from the bottom face (negative z) to the top face (positive z). Ply count multiplies the thickness of a single ply. The composition is weighted by thickness and “other” contains angles outside 0°, ±45° and 90°.

The bank uses one material and one density for the full stack. Membrane constants come from the upper-left compliance block of the inverted ABD matrix at M = 0. The flexural modulus uses the lower-right compliance block at N = 0.

The coupling flag compares |Bᵢⱼ|/√(AᵢᵢDⱼⱼ) with numerical roundoff. Mirrored layups have B = 0 by symmetry. An unbalanced laminate can still have A₁₆ or A₂₆ even with zero B.

Scope. Thin, perfectly bonded, linear elastic plies. Inputs are purely mechanical resultants, with no transverse shear, thermal load or interlaminar stress recovery.

See calculation methods and references