Worked example

Off-angle sensor patch

Estimate forces and induced curvatures for a small patch with a 32° reinforcement block.

The 32° material appears under “other” in the thickness-weighted carpet composition.

View live results

Inputs

Ply material
GPa
GPa
GPa
g/cm³
Ply stack

Enter blocks from the bottom face to the top face.

1
2
3
Membrane loads
N/mm
N/mm
N/mm
Moments per unit width
N
N
N

Live results

SI
Thickness
0.8 mm
Membrane Ex
20.006 GPa
Bending Ex,f
23.779 GPa
Areal mass
1,528 g/m²
Extension–bending coupledCoupling assessed relative to membrane and bending stiffness
Laminate edge section
Scaled laminate stack and thickness-weighted fiber orientation composition +z / TOP−z / BASE0.8 mm0°22.5%±45°0%90°22.5%Other55%
  • 0°
  • ±45°
  • 90°
  • Other
0° fiber thickness share22.5%
0%100% of stack

Engineering constants

Membrane Ey
15.5913 GPa
Membrane Gxy
6.78869 GPa
Membrane νxy
0.284854
Bending Ey,f
20.9292 GPa
Ply count
4
max |Bᵢⱼ|
1,877.91 N

Mid-plane response

ε⁰ x
1,176.91 µε
ε⁰ y
309.204 µε
ε⁰ xy
880.805 µε
κ x
0.00193212 mm⁻¹
κ y
−8.16224e-4 mm⁻¹
κ xy
−5.1788e-4 mm⁻¹

ABD stiffness A N/mm · B N · D N·mm

εxεyγxyκxκyκxy
Nx23,5205,6224,780−1,878−1.705e-13−1.327e-13
Ny5,62217,0301,874−1.705e-131,878−5.203e-14
Nxy4,7801,8746,579−1.327e-13−5.203e-14−2.274e-13
Mx−1,878−1.705e-13−1.327e-131,24418977.12
My−1.705e-131,878−5.203e-141891,14030.24
Mxy−1.327e-13−5.203e-14−2.274e-1377.1230.24240.1

Model and assumptions

A = ΣQ̄ Δz · B = ½ΣQ̄ Δ(z²) · D = ⅓ΣQ̄ Δ(z³) · [N; M] = [A B; B D][ε⁰; κ].

Enter blocks from the bottom face (negative z) to the top face (positive z). Ply count multiplies the thickness of a single ply. The composition is weighted by thickness and “other” contains angles outside 0°, ±45° and 90°.

The bank uses one material and one density for the full stack. Membrane constants come from the upper-left compliance block of the inverted ABD matrix at M = 0. The flexural modulus uses the lower-right compliance block at N = 0.

The coupling flag compares |Bᵢⱼ|/√(AᵢᵢDⱼⱼ) with numerical roundoff. Mirrored layups have B = 0 by symmetry. An unbalanced laminate can still have A₁₆ or A₂₆ even with zero B.

Scope. Thin, perfectly bonded, linear elastic plies. Inputs are purely mechanical resultants, with no transverse shear, thermal load or interlaminar stress recovery.

See calculation methods and references