Stability

Composite plate and column buckling

Sweep axial half-wave modes for a simply supported specially orthotropic plate and compare the Euler strip.

View live results

Inputs

Plate geometry and load
mm
mm
N/mm
Bending stiffness
N·mm
N·mm
N·mm
N·mm

Live results

SI
Plate critical
62.987 N/mm
Euler strip
7.0681 N/mm
Half-waves
2
Load margin
0.16643
PassSSSS plate threshold
Buckling mode branches
Orthotropic buckling coefficient mode branches with active aspect ratio k0.56a/bm* = 2
  • Minimum of 16 modes
  • Modes 1–5
  • Active aspect
Limit utilization85.732%
0%100% limit

Plate stability

Aspect ratio a/b
2
Coefficient k
3.4962
Plate reserve factor
1.16643
Euler strip reserve
0.13089
D11
165,000 N·mm
D12
18,600 N·mm
D22
67,000 N·mm
D66
24,600 N·mm

Axial half-wave sweep

Mode mCritical running load
176.2238 N/mm
262.9873 N/mm
391.9497 N/mm
4139.194 N/mm
5201.773 N/mm
6278.961 N/mm
7370.508 N/mm
8476.309 N/mm
9596.316 N/mm
10730.502 N/mm
11878.851 N/mm
121,041.36 N/mm
131,218.01 N/mm
141,408.81 N/mm
151,613.76 N/mm
161,832.84 N/mm

Model and assumptions

Nx,cr(m) = (π²/b²)[D₁₁(mb/a)² + 2(D₁₂ + 2D₆₆) + D₂₂(a/mb)²].

The plate has four simply supported edges, compression along a and one transverse half-wave. The table sweeps m = 1 through 16. If the minimum lies beyond mode 16, the two integers around the analytical minimum are checked for the governing threshold.

Direct inputs require positive-definite, specially orthotropic bending stiffness. The 0° single-layer option uses D = Qh³/12. The plot normalizes critical load as k = Nx,cr·b²/(π²√(D₁₁D₂₂)).

The pin-ended, unit-width strip value π²D₁₁/a² is a comparison. For a strip with width b the corresponding total axial force is its running load times b.

Scope. Linear bifurcation with D₁₆ = D₂₆ = 0 and no extension–bending coupling, imperfection, transverse shear or postbuckling strength.

See calculation methods and references