Worked example

Long narrow orthotropic strip

Compare the close mode spacing of a slender axial compression panel.

The governing half-wave count can exceed the five plotted individual branches. The active point still uses the full 16-mode sweep.

View live results

Inputs

Plate geometry and load
mm
mm
N/mm
Bending stiffness
N·mm
N·mm
N·mm
N·mm

Live results

SI
Plate critical
362.36 N/mm
Euler strip
1.6313 N/mm
Half-waves
8
Load margin
1.1961
PassSSSS plate threshold
Buckling mode branches
Orthotropic buckling coefficient mode branches with active aspect ratio k0.512.2a/b (log)m* = 8
  • Minimum of 16 modes
  • Modes 1–5
  • Active aspect
Limit utilization45.535%
0%100% limit

Plate stability

Aspect ratio a/b
10
Coefficient k
3.14132
Plate reserve factor
2.19613
Euler strip reserve
0.00988691
D11
200,000 N·mm
D12
18,000 N·mm
D22
100,000 N·mm
D66
31,000 N·mm

Axial half-wave sweep

Mode mCritical running load
18,288.84 N/mm
22,176.21 N/mm
31,051.49 N/mm
4666.402 N/mm
5497.559 N/mm
6415.81 N/mm
7376.906 N/mm
8362.361 N/mm
9363.346 N/mm
10375.208 N/mm
11395.31 N/mm
12422.064 N/mm
13454.468 N/mm
14491.866 N/mm
15533.811 N/mm
16579.992 N/mm

Model and assumptions

Nx,cr(m) = (π²/b²)[D₁₁(mb/a)² + 2(D₁₂ + 2D₆₆) + D₂₂(a/mb)²].

The plate has four simply supported edges, compression along a and one transverse half-wave. The table sweeps m = 1 through 16. If the minimum lies beyond mode 16, the two integers around the analytical minimum are checked for the governing threshold.

Direct inputs require positive-definite, specially orthotropic bending stiffness. The 0° single-layer option uses D = Qh³/12. The plot normalizes critical load as k = Nx,cr·b²/(π²√(D₁₁D₂₂)).

The pin-ended, unit-width strip value π²D₁₁/a² is a comparison. For a strip with width b the corresponding total axial force is its running load times b.

Scope. Linear bifurcation with D₁₆ = D₂₆ = 0 and no extension–bending coupling, imperfection, transverse shear or postbuckling strength.

See calculation methods and references