CompositePlyLab / SI
Long narrow orthotropic strip
Sweep axial half-wave modes for a simply supported specially orthotropic plate and compare the Euler strip.
- Plate critical
- 362.36 N/mm
- Euler strip
- 1.6313 N/mm
- Half-waves
- 8
- Load margin
- 1.1961
Pass · SSSS plate threshold
Inputs
| Stiffness source | Enter D terms |
|---|---|
| Plate length a | 1,100 mm |
| Plate width b | 110 mm |
| Running compression Nx | 165 N/mm |
| Bending stiffness D₁₁ | 200,000 N·mm |
| Bending stiffness D₁₂ | 18,000 N·mm |
| Bending stiffness D₂₂ | 100,000 N·mm |
| Twisting stiffness D₆₆ | 31,000 N·mm |
Results
Plate stability
- Aspect ratio a/b
- 10
- Coefficient k
- 3.14132
- Plate reserve factor
- 2.19613
- Euler strip reserve
- 0.00988691
- D11
- 200,000 N·mm
- D12
- 18,000 N·mm
- D22
- 100,000 N·mm
- D66
- 31,000 N·mm
Axial half-wave sweep
| Mode m | Critical running load |
|---|---|
| 1 | 8,288.84 N/mm |
| 2 | 2,176.21 N/mm |
| 3 | 1,051.49 N/mm |
| 4 | 666.402 N/mm |
| 5 | 497.559 N/mm |
| 6 | 415.81 N/mm |
| 7 | 376.906 N/mm |
| 8 | 362.361 N/mm |
| 9 | 363.346 N/mm |
| 10 | 375.208 N/mm |
| 11 | 395.31 N/mm |
| 12 | 422.064 N/mm |
| 13 | 454.468 N/mm |
| 14 | 491.866 N/mm |
| 15 | 533.811 N/mm |
| 16 | 579.992 N/mm |