CompositePlyLab / SI
Very slender mode ceiling
Sweep axial half-wave modes for a simply supported specially orthotropic plate and compare the Euler strip.
- Plate critical
- 355.38 N/mm
- Euler strip
- 0.070483 N/mm
- Half-waves
- 36
- Load margin
- 0.97431
Marginal · Governing mode above the plotted 1–16 sweep
Inputs
| Stiffness source | Enter D terms |
|---|---|
| Plate length a | 3,550 mm |
| Plate width b | 100 mm |
| Running compression Nx | 180 N/mm |
| Bending stiffness D₁₁ | 90,000 N·mm |
| Bending stiffness D₁₂ | 27,000 N·mm |
| Bending stiffness D₂₂ | 90,000 N·mm |
| Twisting stiffness D₆₆ | 31,500 N·mm |
Results
Plate stability
- Aspect ratio a/b
- 35.5
- Coefficient k
- 4.00078
- Plate reserve factor
- 1.97431
- Euler strip reserve
- 3.91573e-4
- D11
- 90,000 N·mm
- D12
- 27,000 N·mm
- D22
- 90,000 N·mm
- D66
- 31,500 N·mm
Axial half-wave sweep
| Mode m | Critical running load |
|---|---|
| 1 | 112,121 N/mm |
| 2 | 28,163.8 N/mm |
| 3 | 12,616.5 N/mm |
| 4 | 7,175.25 N/mm |
| 5 | 4,657.16 N/mm |
| 6 | 3,289.73 N/mm |
| 7 | 2,465.67 N/mm |
| 8 | 1,931.28 N/mm |
| 9 | 1,565.38 N/mm |
| 10 | 1,304.14 N/mm |
| 11 | 1,111.33 N/mm |
| 12 | 965.188 N/mm |
| 13 | 851.952 N/mm |
| 14 | 762.608 N/mm |
| 15 | 691.038 N/mm |
| 16 | 632.976 N/mm |