ConcreteEarthLab

Worked example

Adjusting a tight stair tread from 9 to 10 in

A constrained straight-flight layout begins with a 9 in tread and 58 in of rise. The starting example shows tread and comfort flags.

Inputs

Measurement system
in
in
For a typical residential stair, start around 7 to 7¾ in.
in
ft
ft
in
in
Measure perpendicular to the slope.
%
STAIR ELEVATIONStraight stair flight, waist and optional top landing. STAIR ELEVATION Rise 58 inRun 5.25 ft8 risers · 7 treadsWaist 6 in · 38.9° pitch

Estimate

Concrete to order
0.812 yd³
  • Residential dimension screen flags tread is below 10 in.
  • The 2R + T comfort check is outside the 24–26 in planning band.
Order volume · equivalent
0.621 m³
80 lb bags
37
Riser count
8
Treads before landing
7
Actual rise per step
7.25 in
Horizontal flight run
5.25 ft
Run including landing
8.25 ft
2R + T comfort check
23.5 in
Slope angle
38.85 °
Waist volume
0.375 yd³
Step wedge volume
0.176 yd³
Landing volume
0.222 yd³
Net concrete
0.773 yd³
Download

Working this example

Starting estimate 0.812 yd³Concrete to order

Set the tread to 10 in and compare run and comfort. If the fit remains tight, review the available opening with the designer.

See the calculator formulas and assumptions

Questions & answers

What is the run penalty for increasing every tread by 1 in in this layout?

There are seven treads, so the extra inch adds 7 in of flight run.

Why can this stair reach the tread screen while staying below the comfort band?

The two checks use different inputs. A 10 in tread meets the basic tread screen, while 2R + T also depends on the actual riser.