ControlLoopLab
Home Digital filtersWorked example

Digital cutoff close to Nyquist

A numerical reference uses a cutoff close to half the sample rate to test coefficient handling.

Model inputs

Filter specification
Hz
Hz
Hz

Discrete transfer & step samples

Below Nyquist
Cutoff gain
−3.0103dB
Test phase
−180°
Test delay
11.239ms
Noise BW
477.84Hz
Discrete low-pass attenuation and step responseDiscrete attenuationdB4075.2141266500−72−47−223Frequency (Hz, log)Unit-step samplesoutput036912−0.08620.330.7471.16Sample index nCutoff markerTest markerStep samples
y[n] = b0 x[n] + b1 x[n−1] + b2 x[n−2] − a1 y[n−1] − a2 y[n−2]

Calculated results

b0
0.9149691441130826
b1
1.8299382882261652
b2
0.9149691441130826
a1
1.822694925196308
a2
0.8371816512560225
DC gain
1×
Cutoff attenuation
−3.0103dB
Cutoff phase
−90°
Cutoff group delay
11.284samples
Cutoff group delay
11.284ms
Test attenuation
−∞dB
Test phase
−180°
Test group delay
11.239samples
Test group delay
11.239ms
95% first crossing
1ms
99% first crossing
1ms
Equivalent noise bandwidth
477.84Hz

Model and interpretation

Full methodology

Set cutoff in digital frequency

Cutoff is strictly between DC and Nyquist. EMA uses the exact digital half-power coefficient. Tustin and Butterworth prewarp the cutoff before bilinear conversion. The denominator uses a0 = 1 and the negative-feedback convention shown above.

Read phase and delay separately

Phase is ∠H(eʲω). Group delay is −d∠H/dω in samples and can differ sharply from phase delay. At a Nyquist transmission zero the displayed phase is the one-sided limit. The noise bandwidth is the one-sided integral of |H|² at unity DC.

Check how the firmware represents it

Step times show the first sample at or past 95% and 99%, with the input step at n = 0. Near DC or Nyquist, implement a suitable factored or high-precision realization and recheck coefficient quantization.