Servo lead with 40° peak boost
A servo needs phase boost near crossover without adding another integrator.
Model inputs
- Architecture
- Phase lead
- Sample rate
- 2500 Hz
- Design center
- 90 Hz
- Peak phase change magnitude
- 40 °
- Gain normalization
- Unity at DC
Model inputs
Realized compensator frequency response
Phase leadCheck the model inputs
- Peak boost
- 40°
- Corner ratio
- 4.5989×
- DC gain
- 1×
- High-freq gain
- 4.5989×
Calculated results
- Prototype zero ωz
- 263.69rad/s
- Prototype pole ωp
- 1212.7rad/s
- Center gain
- 2.1445×
- DC gain
- 1×
- DC level
- 0dB
- High-frequency gain
- 4.5989×
- HF / DC gain ratio
- 4.5989×
- b0
- 3.8939974457779427
- b1
- -3.50226078126992
- b2
- 0
- a1
- -0.6082633354919776
- a2
- 0
- Prewarping preserves the phase boost peak at the requested digital center. Check the high-frequency gain.
Model and interpretation
Full methodologyPlace the peak phase change
The unwarped lead prototype places its zero at ωm/√α and pole at ωm√α. Lag interchanges the pole and zero and reverses the phase sign. The high-frequency to DC gain ratios are α for lead and 1/α for lag.
Check notch width and crossover lag
The notch zero damping is strictly smaller than its pole damping. The half-power edges exist only for ζz/ζp ≤ 1/√2. A wider notch can reduce phase reserve far below the resonance. Compare the realized penalty at the intended loop crossover.
Transfer the digital coefficients
The bilinear transform is prewarped at the design center. Coefficients use the same a0 = 1 and negative-feedback convention as the IIR calculator. Recheck pole stability and quantization in the target realization.