Uphill steady pull
Fsteady = W(sin α + μ cos α)
A percent grade converts by α = atan(grade/100). Friction applies to the ramp-normal load.
Static ramp and haul-line forces
A 33 US ton transformer travels on rollers up a 27% grade. The selected haul arrangement uses three supporting parts.
Schematic geometry. Margin bars mark 100% of the entered limit.
Compare the haul line with the independent holdback. On a steep grade the gravity component can dominate the contact resistance.
Ramp pull to start movement 21,186.34 lbf · Ramp pull during steady travel 20,389.86 lbf
Fsteady = W(sin α + μ cos α)
A percent grade converts by α = atan(grade/100). Friction applies to the ramp-normal load.
Fstart = W(sin α + μstart cos α)
μstart is steady μ × breakaway multiplier. Apply the entered reserve, then divide by purchase parts × aggregate efficiency.
H = reserve × W sin α
The independent inline downhill restraint receives no friction credit. An anchor at a redirect sheave carries the vector sum of rope tensions.
Use measured or reviewed friction values. Confirm the working-layer winch rating, anchor load path, braking, surface integrity and route geometry with a qualified team. Snagging, side pulls and transient forces can govern.
CraneRiggingLab · Lift screening worksheet
Static ramp and haul-line forces · US · short ton
Screening estimates only. Have a qualified rigger and a professional engineer (PE), where required, review the lift plan. Use the OEM chart for the actual configuration.
Use measured or reviewed friction values. Confirm the working-layer winch rating, anchor load path, braking, surface integrity and route geometry with a qualified team. Snagging, side pulls and transient forces can govern.