ASME B30.20 · ASME BTH-1

Spreader Bar vs. Lifting Beam

Compare end-loaded spreader compression with center-picked lifting beam bending, and estimate the difference in headroom.

Inputs

Load and geometry
lb
ft
°
ft
lbf·ft
Spreader pipe properties
in
in
Msi
ksi
×
×
Back to results ↑

Results

Static screeningEdit inputs ↓
Spreader and lifting beam free bodiesCOMPRESSION12,000lbfBEAM MOMENT84,000lbf·ftEULER LOAD285,463lbfHEIGHT SAVED5ftSPREADER BARLIFTING BEAMAXIAL COMPRESSIONCENTER BENDINGSpreader axial limit23.93%Beam moment limit84%Sling tensionMember reactionReference or heightLift screening only · verify with rigger / PE and OEM chart

Schematic geometry. Margin bars mark 100% of the entered limit.

Screening results

Compare these results with the approved equipment and lift plan.

Spreader axial compression
12,000 lbf
Lifting beam peak bending
84,000 lbf·ft
Ideal Euler buckling load
285,463.05 lbf
Headroom saved with beam
5 ft
Pipe slenderness, KL/r
74.82
E3 axial load at screening factor
50,138.58 lbf
Tension per upper sling
16,970.56 lbf
Spreader hook rise above pickup
7 ft

Spreader force

C = (W/2) / tan θ

Assume symmetric vertical bottom drops and one centered upper hook. Top sling tension is W/(2 sin θ).

Pipe buckling

Pₑ = π²EI / (KL)²

The AISC E3 flexural column curve reduces elastic or inelastic strength for a non-slender round steel section. Divide its nominal strength by the entered screening factor.

Beam comparison

M = WL/4; ΔH = (L/2) tan θ − Hbeam

Assume symmetrical end forces and a single center pick. Compare equal reference points for headroom.

Use a rated device or a design verified to ASME BTH-1 and B30.20. The axial comparison uses a structural-steel flexural model only. Review slender walls, eccentricity, lateral instability, welds, fatigue, hardware and applicable device design factors separately.

Worked examples