ASME B30.20 · ASME BTH-1

Short pipe spreader in the inelastic buckling range

A 12 metric t assembly has a short 1.8 m spread and a large pipe section. A high ideal Euler value is expected.

Inputs

Load and geometry
metric t
m
°
m
kN·m
Spreader pipe properties
mm
mm
GPa
MPa
×
×
Back to results ↑

Results

Static screeningEdit inputs ↓
Spreader and lifting beam free bodiesCOMPRESSION33.97kNBEAM MOMENT52.96kN·mEULER LOAD37,956.87kNHEIGHT SAVED1.11mSPREADER BARLIFTING BEAMAXIAL COMPRESSIONCENTER BENDINGSpreader axial limit4.52%Beam moment limit52.96%Sling tensionMember reactionReference or heightLift screening only · verify with rigger / PE and OEM chart

Schematic geometry. Margin bars mark 100% of the entered limit.

Screening results

Compare these results with the approved equipment and lift plan.

Spreader axial compression
33.97 kN
Lifting beam peak bending
52.96 kN·m
Ideal Euler buckling load
37,956.87 kN
Headroom saved with beam
1.11 m
Pipe slenderness, KL/r
21.93
E3 axial load at screening factor
751.3 kN
Tension per upper sling
67.94 kN
Spreader hook rise above pickup
1.56 m

The E3 column curve gives a lower strength than the gross yield force. A rated device still needs review of local details and connections.

Spreader axial compression 33.97 kN · Lifting beam peak bending 52.96 kN·m

Spreader force

C = (W/2) / tan θ

Assume symmetric vertical bottom drops and one centered upper hook. Top sling tension is W/(2 sin θ).

Pipe buckling

Pₑ = π²EI / (KL)²

The AISC E3 flexural column curve reduces elastic or inelastic strength for a non-slender round steel section. Divide its nominal strength by the entered screening factor.

Beam comparison

M = WL/4; ΔH = (L/2) tan θ − Hbeam

Assume symmetrical end forces and a single center pick. Compare equal reference points for headroom.

Use a rated device or a design verified to ASME BTH-1 and B30.20. The axial comparison uses a structural-steel flexural model only. Review slender walls, eccentricity, lateral instability, welds, fatigue, hardware and applicable device design factors separately.

Other worked examples