Spreader force
C = (W/2) / tan θ
Assume symmetric vertical bottom drops and one centered upper hook. Top sling tension is W/(2 sin θ).
ASME B30.20 · ASME BTH-1
A 12 metric t assembly has a short 1.8 m spread and a large pipe section. A high ideal Euler value is expected.
Schematic geometry. Margin bars mark 100% of the entered limit.
Compare these results with the approved equipment and lift plan.
The E3 column curve gives a lower strength than the gross yield force. A rated device still needs review of local details and connections.
Spreader axial compression 33.97 kN · Lifting beam peak bending 52.96 kN·m
C = (W/2) / tan θ
Assume symmetric vertical bottom drops and one centered upper hook. Top sling tension is W/(2 sin θ).
Pₑ = π²EI / (KL)²
The AISC E3 flexural column curve reduces elastic or inelastic strength for a non-slender round steel section. Divide its nominal strength by the entered screening factor.
M = WL/4; ΔH = (L/2) tan θ − Hbeam
Assume symmetrical end forces and a single center pick. Compare equal reference points for headroom.
Use a rated device or a design verified to ASME BTH-1 and B30.20. The axial comparison uses a structural-steel flexural model only. Review slender walls, eccentricity, lateral instability, welds, fatigue, hardware and applicable device design factors separately.
CraneRiggingLab · Lift screening worksheet
ASME B30.20 · ASME BTH-1 · SI · metric t
Screening estimates only. Have a qualified rigger and a professional engineer (PE), where required, review the lift plan. Use the OEM chart for the actual configuration.
Use a rated device or a design verified to ASME BTH-1 and B30.20. The axial comparison uses a structural-steel flexural model only. Review slender walls, eccentricity, lateral instability, welds, fatigue, hardware and applicable device design factors separately.