API 421-style rectangular bay

Size a horizontal decanter or API-style bay from droplet rise or settling, residence time and seal-leg head.

An oily-water stream of 110 m³/h carries 150 µm droplets into an API-style rectangular bay.

Droplet speed
1.805 mm/s
Droplet Re
0.2454
Overflow area
16.93 m²
Seal crest
0.9705 m

Oil–water interface and heavy-phase seal leg

Live schematic
Horizontal decanter showing light and heavy layers with hydrostatic seal legOIL DROPLETS RISE1.81 mm/sINTERFACE0.871 mSEAL CREST0.97 m12.7 m × 2.3 mLight liquidHeavy liquidVessel datum
Within Stokes screen

Droplet Reynolds number is at or below 1 under the entered continuous-phase conditions.

Droplet Reynolds number vs Stokes limit0.245
Review marker 1 Screen limit 1

Worked solution

  1. Check the droplet regime

    Stokes gives 1.805 mm/s at Re = 0.2454. The ideal projected overflow area is 16.93 m².

  2. Size for overflow and hold-up

    Use the chosen geometry, a separation area of 24.74 m² and the continuous-phase residence target. Size to 12.66 m × 2.302 m at 13.85 min of hold-up.

  3. Balance the liquid heads

    At liquid level 0.9898 m and interface 0.871 m, the heavy-phase seal crest is 0.9705 m above the bottom.

Size for corrected overflow area and vertical cross-sectional velocity, then verify the geometry screen. The derivation uses SI units.

Calculation details
Design separation area24.74 m²
Sized separation area29.14 m²
Separator length12.66 m
Bay width or vessel bore2.302 m
Total operating liquid depth0.9898 m
Liquid interface elevation0.871 m
Continuous-phase hold-up25.38 m³
Continuous-phase residence time13.85 min
Bulk horizontal velocity0.01524 m/s
API-style horizontal velocity cap0.01524 m/s
Short-circuit / turbulence factor1.462

Calculation inputs

Live updates

Phases and throughput
kg/m³
kg/m³
mPa·s
µm
m³/h
Vessel and interface
min
%
%
Back to results

Equations and assumptions

Stokes velocity
vt = g dp² |ρc − ρd| / (18 μc)
Regime check
Rep = ρc vt dp / μc
Ideal overflow area
Ah = Qc / vt
Seal-leg crest
z = hi + (ρlight/ρheavy)(H − hi)

The circular decanter uses the interfacial chord in the separation area and a circular segment for continuous-phase hold-up. The rectangular bay sizes for corrected overflow area, residence time and a bulk horizontal velocity at most the lesser of 15 vt and 3 ft/min.

The API-style sizing includes an interpolated turbulence and short-circuit factor at the allowed velocity. It checks representative geometry criteria for oil rising in water. The Stokes model assumes dilute spherical droplets and is screened at Rep ≤ 1.

The seal-leg crest is measured from the vessel bottom at equal gas pressure on the two sides. Dynamic head losses, nozzle allowances and emulsions require separate evaluation.

Method references