DistillColumnLab
Menu

Worked example · Liquid–liquid separation

Large droplets outside Stokes flow

Size a horizontal decanter or API-style bay from droplet rise or settling, residence time and seal-leg head.

Check 850 µm dispersed droplets in a water-like continuous phase.

Droplet speed
77.91 mm/s
Droplet Re
68.07
Overflow area
0.04278 m²
Seal crest
0.7722 m

Oil–water interface and heavy-phase seal leg

Live schematic
Horizontal decanter showing light and heavy layers with hydrostatic seal legOIL DROPLETS RISE77.9 mm/sINTERFACE0.538 mSEAL CREST0.772 m4.36 m × 1.09 mLight liquidHeavy liquidVessel datum
Outside Stokes regime

The Stokes velocity and the resulting dimensions need a drag model for this droplet Reynolds number.

Droplet Reynolds number vs Stokes limit68.1
Review marker 1 Screen limit 1

Worked solution

  1. Check the droplet regime

    Stokes gives 77.91 mm/s at Re = 68.07. The ideal projected overflow area is 0.04278 m².

  2. Size for overflow and hold-up

    Use the chosen geometry, a separation area of 0.04278 m² and the continuous-phase residence target. Size to 4.358 m × 1.089 m at 10 min of hold-up.

  3. Balance the liquid heads

    At liquid level 0.828 m and interface 0.5382 m, the heavy-phase seal crest is 0.7722 m above the bottom.

A droplet Reynolds number above 1 marks the Stokes-derived dimensions for review. The derivation uses SI units.

Calculation details
Design separation area0.04278 m²
Sized separation area4.747 m²
Separator length4.358 m
Bay width or vessel bore1.089 m
Total operating liquid depth0.828 m
Liquid interface elevation0.5382 m
Continuous-phase hold-up2 m³
Continuous-phase residence time10 min
Bulk horizontal velocity0.007263 m/s
API-style horizontal velocity cap— m/s
Short-circuit / turbulence factor1

Calculation inputs

Live updates

Phases and throughput
kg/m³
kg/m³
mPa·s
µm
m³/h
Vessel and interface
min
%
%
Back to results

Equations and assumptions

Stokes velocity
vt = g dp² |ρc − ρd| / (18 μc)
Regime check
Rep = ρc vt dp / μc
Ideal overflow area
Ah = Qc / vt
Seal-leg crest
z = hi + (ρlight/ρheavy)(H − hi)

The circular decanter uses the interfacial chord in the separation area and a circular segment for continuous-phase hold-up. The rectangular bay sizes for corrected overflow area, residence time and a bulk horizontal velocity at most the lesser of 15 vt and 3 ft/min.

The API-style sizing includes an interpolated turbulence and short-circuit factor at the allowed velocity. It checks representative geometry criteria for oil rising in water. The Stokes model assumes dilute spherical droplets and is screened at Rep ≤ 1.

The seal-leg crest is measured from the vessel bottom at equal gas pressure on the two sides. Dynamic head losses, nozzle allowances and emulsions require separate evaluation.

Method references