Oil droplets rising in water

Size a horizontal decanter or API-style bay from droplet rise or settling, residence time and seal-leg head.

A circular horizontal decanter removes 150 µm oil droplets from a 28 m³/h water stream.

Droplet speed
1.805 mm/s
Droplet Re
0.2454
Overflow area
4.308 m²
Seal crest
1.036 m

Oil–water interface and heavy-phase seal leg

Live schematic
Horizontal decanter showing light and heavy layers with hydrostatic seal legOIL DROPLETS RISE1.81 mm/sINTERFACE0.714 mSEAL CREST1.04 m5.78 m × 1.44 mLight liquidHeavy liquidVessel datum
Within Stokes screen

Droplet Reynolds number is at or below 1 under the entered continuous-phase conditions.

Droplet Reynolds number vs Stokes limit0.245
Review marker 1 Screen limit 1

Worked solution

  1. Check the droplet regime

    Stokes gives 1.805 mm/s at Re = 0.2454. The ideal projected overflow area is 4.308 m².

  2. Size for overflow and hold-up

    Use the chosen geometry, a separation area of 4.308 m² and the continuous-phase residence target. Size to 5.78 m × 1.445 m at 10 min of hold-up.

  3. Balance the liquid heads

    At liquid level 1.098 m and interface 0.7138 m, the heavy-phase seal crest is 1.036 m above the bottom.

The droplet rise rate sets the overflow area. The continuous-phase segment sets residence volume. The derivation uses SI units.

Calculation details
Design separation area4.308 m²
Sized separation area8.351 m²
Separator length5.78 m
Bay width or vessel bore1.445 m
Total operating liquid depth1.098 m
Liquid interface elevation0.7138 m
Continuous-phase hold-up4.667 m³
Continuous-phase residence time10 min
Bulk horizontal velocity0.009633 m/s
API-style horizontal velocity cap— m/s
Short-circuit / turbulence factor1

Calculation inputs

Live updates

Phases and throughput
kg/m³
kg/m³
mPa·s
µm
m³/h
Vessel and interface
min
%
%
Back to results

Equations and assumptions

Stokes velocity
vt = g dp² |ρc − ρd| / (18 μc)
Regime check
Rep = ρc vt dp / μc
Ideal overflow area
Ah = Qc / vt
Seal-leg crest
z = hi + (ρlight/ρheavy)(H − hi)

The circular decanter uses the interfacial chord in the separation area and a circular segment for continuous-phase hold-up. The rectangular bay sizes for corrected overflow area, residence time and a bulk horizontal velocity at most the lesser of 15 vt and 3 ft/min.

The API-style sizing includes an interpolated turbulence and short-circuit factor at the allowed velocity. It checks representative geometry criteria for oil rising in water. The Stokes model assumes dilute spherical droplets and is screened at Rep ≤ 1.

The seal-leg crest is measured from the vessel bottom at equal gas pressure on the two sides. Dynamic head losses, nozzle allowances and emulsions require separate evaluation.