Worked example · Distillation
Close-boiling key separation
Estimate minimum reflux, theoretical stages, actual trays and feed location for a binary split.
The key volatility ratio is 1.12. Target a 90 mol% light-key overhead and 12 mol% bottoms.
- Min stages
- 36.97
- Min reflux
- 14.58
- Theory stages
- 67.32
- Actual trays
- 93
McCabe–Thiele construction
Live schematicA tight split, low reflux margin or limited staircase warrants a rigorous stage model.
Calculation inputs
- Relative volatility α
- 1.12
- Feed light key xF
- 0.46
- Distillate light key xD
- 0.9
- Bottoms light key xB
- 0.12
- Feed quality q
- 1
- Reflux multiplier R/Rmin
- 1.3
- Overall stage efficiency
- 72 %
Worked solution
- Get the total-reflux stage floor
Use α = 1.12, xD = 0.9 and xB = 0.12 in the Fenske log-odds ratio. Nmin = 36.97.
- Find the reflux floor
Bracket the feed-quality root between 1 and α. At θ = 1.06141, the product equation gives Rmin = 14.58. Multiply by 1.3 to get R = 18.95.
- Size trays and allocate the sections
Gilliland gives 67.32 stages. Remove the equilibrium reboiler and apply Eₒ = 72 % to get 93 trays. Kirkbride gives NR/NS = 1.175 and feed tray 51 from the top.
The minimum stage count rises rapidly as α approaches 1. Only the visible prefix of a long staircase is drawn. The derivation uses SI units.
| Underwood root θ | 1.06141 |
|---|---|
| Operating reflux R | 18.95 |
| Distillate recovery D/F | 43.59 % |
| Bottoms split B/F | 56.41 % |
| Kirkbride stage ratio NR/NS | 1.175 |
| Feed tray from top | 51 |
| Condenser vapor V/D | 19.95 |
| Reboiler vapor V̄/B | 15.41 |
| Rectifying vapor V/F | 8.696 |
| Stripping vapor V̄/F | 8.696 |
Calculation inputs
Live updates
Equations and assumptions
- Minimum stages
- Nmin = [logit(xD) − logit(xB)] / ln(α)
- Minimum reflux
- Σ αᵢ zᵢ / (αᵢ − θ) = 1 − q
- Reflux and stages
- X = (R − Rmin)/(R + 1) · Y = (N − Nmin)/(N + 1)
- Feed-stage split
- NR/NS = [(B/D)((1−xF)/xF)(xB/(1−xD))²]^0.206
The model uses constant relative volatility, constant molar overflow, a total condenser and one equilibrium reboiler. The theoretical total includes the reboiler. The actual tray count applies efficiency after subtracting that reboiler.
Gilliland uses the Molokanov exponential fit. Kirkbride estimates the section split and the feed tray is rounded from the top of the column. The McCabe–Thiele staircase uses the two material-balance operating lines at the entered reflux and may give a different stage count.
q below 0 represents superheated vapor and q above 1 represents subcooled liquid. The reflux multiplier requires positive minimum reflux and positive internal stripping flows.