DistillColumnLab
Menu

Worked example · Gas thermodynamics

Custom fluid at a 60 °F reference

Solve Peng–Robinson or Redlich–Kwong for density and convert standard to actual gas volume at equal mass flow.

Enter a custom light gas and a 60 °F reference temperature for a metering basis.

Z factor
0.79216
Gas density
80.88 kg/m³
Actual flow
8.803 Am³/h
Standard flow
750 Nm³/h

Vapor-branch compressibility isotherm

Live schematic
Compressibility versus absolute pressure along the selected isotherm02,2204,4406,6608,8800.7430.8120.8810.951.019COMPRESSIBILITY ZPRESSURE kPa absISOTHERM38 °COPERATING Z0.79216ADMISSIBLE ROOTS1EOS vapor rootIdeal gasOperating point
Real-gas correction material

The 5% deviation marker compares the operating compressibility to Z = 1.

Absolute compressibility departure |Z − 1|20.8 %
Review marker 5 % Screen limit 10 %

Worked solution

  1. Solve both EOS states

    At the operating pressure of 7,400 kPa abs, the largest admissible root is 0.7921565. At the reference state it is 0.9959616.

  2. Get densities and conserve mass

    Evaluate P MW/(ZRT) at both states for 80.88 kg/m³ actual and 0.9494 kg/m³ reference. The stream carries 712 kg/h.

  3. Convert volumetric flow

    Divide that mass flow by the density at each state. The result is 8.803 Am³/h actual and 750 Nm³/h standard.

Changing the reference condition changes the standard volume. Switching display units preserves that same condition. The derivation uses SI units.

Calculation details
Mass flow712 kg/h
Reference compressibility0.995962
Reference density0.9494 kg/m³
Operating reduced temperature1.371
Operating reduced pressure1.574
Operating EOS coefficient A0.3219
Operating EOS coefficient B0.08937
Scaled cubic residual2.053e-17

Admissible roots 0.7921565

Calculation inputs

Live updates

Gas and equation
kg/kmol
°C
bar abs
Operating and reference states
°C
kPa abs
°C
kPa abs
Volume flow

Both unit systems use the reference state shown above.

Nm³/h
Back to results

Equations and assumptions

Peng–Robinson cubic
Z³ − (1−B)Z² + (A−2B−3B²)Z − (AB−B²−B³) = 0
Redlich–Kwong cubic
Z³ − Z² + (A−B−B²)Z − AB = 0
Gas density
ρ = P MW / (Z R T)
Volume conversion
Qs ρs = Qa ρa

A scaled Cardano solver with Newton refinement returns the largest real admissible root Z > B. The subcritical flag requests a phase-stability check. The gas preset is a pure-fluid or pseudo-pure approximation without mixing rules.

The reference state defaults to 0 °C and 101.325 kPa absolute. Nm³/h and SCFM labels both use the entered reference temperature and absolute pressure, so toggling units preserves the reference condition. Set the reference state required by your metering convention.

Method references