DistillColumnLab
Menu

Worked example · Gas thermodynamics

Compressed nitrogen with Redlich–Kwong

Solve Peng–Robinson or Redlich–Kwong for density and convert standard to actual gas volume at equal mass flow.

Use Redlich–Kwong for nitrogen at 25 °C and 120 bar absolute with an entered actual flow.

Z factor
0.99325
Gas density
136.5 kg/m³
Actual flow
14 Am³/h
Standard flow
1,528 Nm³/h

Vapor-branch compressibility isotherm

Live schematic
Compressibility versus absolute pressure along the selected isotherm03,6007,20010,80014,4000.97430.9840.99381.0031.013COMPRESSIBILITY ZPRESSURE kPa absISOTHERM25 °COPERATING Z0.99325ADMISSIBLE ROOTS1EOS vapor rootIdeal gasOperating point
Near ideal-gas behavior

The 5% deviation marker compares the operating compressibility to Z = 1.

Absolute compressibility departure |Z − 1|0.675 %
Review marker 5 % Screen limit 10 %

Worked solution

  1. Solve both EOS states

    At the operating pressure of 12,000 kPa abs, the largest admissible root is 0.9932461. At the reference state it is 0.9993471.

  2. Get densities and conserve mass

    Evaluate P MW/(ZRT) at both states for 136.5 kg/m³ actual and 1.251 kg/m³ reference. The stream carries 1,911 kg/h.

  3. Convert volumetric flow

    Divide that mass flow by the density at each state. The result is 14 Am³/h actual and 1,528 Nm³/h standard.

Solve the standard and actual roots independently before converting volume. The derivation uses SI units.

Calculation details
Mass flow1,911 kg/h
Reference compressibility0.999347
Reference density1.251 kg/m³
Operating reduced temperature2.363
Operating reduced pressure3.534
Operating EOS coefficient A0.1761
Operating EOS coefficient B0.1296
Scaled cubic residual1.547e-17

Admissible roots 0.9932461

Calculation inputs

Live updates

Gas and equation
kg/kmol
°C
bar abs
Operating and reference states
°C
kPa abs
°C
kPa abs
Volume flow

Both unit systems use the reference state shown above.

Am³/h
Back to results

Equations and assumptions

Peng–Robinson cubic
Z³ − (1−B)Z² + (A−2B−3B²)Z − (AB−B²−B³) = 0
Redlich–Kwong cubic
Z³ − Z² + (A−B−B²)Z − AB = 0
Gas density
ρ = P MW / (Z R T)
Volume conversion
Qs ρs = Qa ρa

A scaled Cardano solver with Newton refinement returns the largest real admissible root Z > B. The subcritical flag requests a phase-stability check. The gas preset is a pure-fluid or pseudo-pure approximation without mixing rules.

The reference state defaults to 0 °C and 101.325 kPa absolute. Nm³/h and SCFM labels both use the entered reference temperature and absolute pressure, so toggling units preserves the reference condition. Set the reference state required by your metering convention.

Method references