Peng–Robinson · Redlich–Kwong
Real-gas Z factor and flow
Solve Peng–Robinson or Redlich–Kwong for density and convert standard to actual gas volume at equal mass flow.
- Z factor
- 0.90227
- Gas density
- 36.68 kg/m³
- Actual flow
- 19.57 Am³/h
- Standard flow
- 1,000 Nm³/h
Vapor-branch compressibility isotherm
Live schematicThe 5% deviation marker compares the operating compressibility to Z = 1.
Calculation inputs
- Gas preset
- Methane
- Equation of state
- Peng–Robinson
- Molecular weight MW
- 16.04 kg/kmol
- Critical temperature Tc
- -82.59 °C
- Critical pressure Pc
- 45.99 bar abs
- Acentric factor ω
- 0.01142
- Operating temperature
- 30 °C
- Operating pressure
- 5,200 kPa abs
- Reference temperature
- 0 °C
- Reference pressure
- 101.3 kPa abs
- Entered flow basis
- Standard volume
- Entered volume flow
- 1,000 Nm³/h
| Mass flow | 717.9 kg/h |
|---|---|
| Reference compressibility | 0.997025 |
| Reference density | 0.7179 kg/m³ |
| Operating reduced temperature | 1.591 |
| Operating reduced pressure | 1.131 |
| Operating EOS coefficient A | 0.1646 |
| Operating EOS coefficient B | 0.05529 |
| Scaled cubic residual | 1.791e-17 |
Admissible roots 0.9022685
Calculation inputs
Live updates
Equations and assumptions
- Peng–Robinson cubic
- Z³ − (1−B)Z² + (A−2B−3B²)Z − (AB−B²−B³) = 0
- Redlich–Kwong cubic
- Z³ − Z² + (A−B−B²)Z − AB = 0
- Gas density
- ρ = P MW / (Z R T)
- Volume conversion
- Qs ρs = Qa ρa
A scaled Cardano solver with Newton refinement returns the largest real admissible root Z > B. The subcritical flag requests a phase-stability check. The gas preset is a pure-fluid or pseudo-pure approximation without mixing rules.
The reference state defaults to 0 °C and 101.325 kPa absolute. Nm³/h and SCFM labels both use the entered reference temperature and absolute pressure, so toggling units preserves the reference condition. Set the reference state required by your metering convention.