Worked example · Distillation
High-purity overhead tray count
Estimate minimum reflux, theoretical stages, actual trays and feed location for a binary split.
A high-purity split targets 99.5 mol% overhead and 2 mol% bottoms with 58% overall stage efficiency.
- Min stages
- 8.77
- Min reflux
- 0.8472
- Theory stages
- 18.56
- Actual trays
- 31
McCabe–Thiele construction
Live schematicInternal liquid and vapor flows are positive. The staircase is an independent equilibrium-stage construction.
Calculation inputs
- Relative volatility α
- 2.85
- Feed light key xF
- 0.62
- Distillate light key xD
- 0.995
- Bottoms light key xB
- 0.02
- Feed quality q
- 1
- Reflux multiplier R/Rmin
- 1.4
- Overall stage efficiency
- 58 %
Worked solution
- Get the total-reflux stage floor
Use α = 2.85, xD = 0.995 and xB = 0.02 in the Fenske log-odds ratio. Nmin = 8.77.
- Find the reflux floor
Bracket the feed-quality root between 1 and α. At θ = 1.327434, the product equation gives Rmin = 0.8472. Multiply by 1.4 to get R = 1.186.
- Size trays and allocate the sections
Gilliland gives 18.56 stages. Remove the equilibrium reboiler and apply Eₒ = 58 % to get 31 trays. Kirkbride gives NR/NS = 1.453 and feed tray 19 from the top.
Apply efficiency to the stages inside the shell after accounting for the equilibrium reboiler. The derivation uses SI units.
| Underwood root θ | 1.32743 |
|---|---|
| Operating reflux R | 1.186 |
| Distillate recovery D/F | 61.54 % |
| Bottoms split B/F | 38.46 % |
| Kirkbride stage ratio NR/NS | 1.453 |
| Feed tray from top | 19 |
| Condenser vapor V/D | 2.186 |
| Reboiler vapor V̄/B | 3.498 |
| Rectifying vapor V/F | 1.345 |
| Stripping vapor V̄/F | 1.345 |
Calculation inputs
Live updates
Equations and assumptions
- Minimum stages
- Nmin = [logit(xD) − logit(xB)] / ln(α)
- Minimum reflux
- Σ αᵢ zᵢ / (αᵢ − θ) = 1 − q
- Reflux and stages
- X = (R − Rmin)/(R + 1) · Y = (N − Nmin)/(N + 1)
- Feed-stage split
- NR/NS = [(B/D)((1−xF)/xF)(xB/(1−xD))²]^0.206
The model uses constant relative volatility, constant molar overflow, a total condenser and one equilibrium reboiler. The theoretical total includes the reboiler. The actual tray count applies efficiency after subtracting that reboiler.
Gilliland uses the Molokanov exponential fit. Kirkbride estimates the section split and the feed tray is rounded from the top of the column. The McCabe–Thiele staircase uses the two material-balance operating lines at the entered reflux and may give a different stage count.
q below 0 represents superheated vapor and q above 1 represents subcooled liquid. The reflux multiplier requires positive minimum reflux and positive internal stripping flows.