Worked example · Gas–solid separation
Lapple general-purpose cyclone
Estimate d₅₀, target-particle capture, pressure drop and inlet velocity for a tangential gas cyclone.
A Lapple general-purpose unit processes 3,600 actual m³/h at a 720 mm barrel diameter.
- Cut size d₅₀
- 4.729 µm
- Grade capture
- 68.66 %
- Inlet speed
- 15.43 m/s
- Pressure drop
- 1.124 kPa
Cyclone vortex and grade-efficiency curve
Live schematicThe inlet velocity falls within the 10–20 m/s screening band.
Calculation inputs
- Inlet gas flow Qg
- 3,600 Am³/h
- Gas density ρg
- 1.18 kg/m³
- Gas viscosity μ
- 0.0184 mPa·s
- Particle density ρp
- 2,500 kg/m³
- Target particle diameter
- 7 µm
- Effective turns Ne
- 5.5
- Geometry preset
- Lapple general purpose
- Barrel diameter Dc
- 0.72 m
- Inlet height a/D
- 0.5
- Inlet width b/D
- 0.25
- Gas outlet De/D
- 0.5
- Finder immersion S/D
- 0.625
- Barrel height h/D
- 2
- Overall height H/D
- 4
- Dust outlet B/D
- 0.25
Worked solution
- Find the inlet velocity
At an inlet area of 0.0648 m², the actual gas flow gives vi = 15.43 m/s.
- Calculate the grade point
Lapple gives a 50% cut of 4.729 µm. At 7 µm, the fractional capture is 68.66 %.
- Evaluate static pressure loss
The geometry gives 8 velocity heads. Multiplying by ½ρg vi² yields 1.124 kPa.
The wider inlet changes inlet velocity, pressure drop and cut size. The derivation uses SI units.
| Shepherd–Lapple velocity heads NH | 8 |
|---|---|
| Tangential inlet area | 0.0648 m² |
| Inlet height | 360 mm |
| Inlet width | 180 mm |
| Vortex finder bore | 360 mm |
| Overall body height | 2.88 m |
Calculation inputs
Live updates
Equations and assumptions
- Inlet velocity
- vi = Qg/(a · b)
- Cut diameter
- d₅₀ = √[9 μ b / (2π Ne vi (ρp − ρg))]
- Fractional capture
- η = 1/[1 + (d₅₀/dp)²]
- Pressure drop
- ΔP = 0.5 ρg vi² NH · NH = 16 a b/De²
Preset dimensions are published standard proportions. The pressure-drop coefficient is the Shepherd–Lapple estimate for a standard tangential inlet. Effective turns are an explicit Lapple model input.
The grade curve predicts collection at one particle diameter. Overall mass efficiency additionally requires a particle-size distribution. The meter marks a 20 m/s screening ceiling, with an additional high-velocity flag above 25 m/s.