DistillColumnLab
Menu

Worked example · Packed beds

Packed-bed retrofit shell check

Estimate GPDC flood capacity, then convert overall gas transfer units into packed height.

An existing 630 mm shell receives the design gas load. Compare its flooding point with the target-sized shell.

Required ID
0.7901 m
% flood
110.1 %
Gas NTU
3.236
Bed height
2.103 m

GPDC capacity curve and packed bed

Live schematic
GPDC capacity curve with a packed bed cross-section0.010.0320.10.32100.0350.0710.110.14C-FACTOR m/sFLOW PARAMETER Fₗᵥ2.1 mFlood curveTarget loadOperating point
At or above predicted flood

Increase the operating area or reduce the vapor load.

Superficial gas velocity ÷ predicted flood110 %
Review marker 80 % Screen limit 100 %

Worked solution

  1. Locate the hydraulic duty

    The liquid and gas mass flows give FLV = 0.07399. The selected correlation gives Cf = 0.09388 m/s and Uf = 1.936 m/s.

  2. Size area for the target fraction

    At 70 % of flood the required shell is 0.7901 m. The checked shell runs at 110.1 % of the predicted limit.

  3. Integrate the driving force

    A = 1.736 gives terminal forces of 0.00735 and 0.02896. The integral gives 3.236 transfer units, which at 0.65 m per unit requires 2.103 m of packing.

The chart point uses the checked shell diameter and moves relative to the predicted flood curve. The derivation uses SI units.

Calculation details
Flow parameter FLV0.07399
Flooding C-factor0.09388 m/s
Flood velocity1.936 m/s
Operating superficial velocity2.131 m/s
Checked shell ID0.63 m
Operating gas flow2,391 Am³/h
Kister–Gill flood gradient (reference)944 Pa/m
Absorption factor A1.736
Lean-end driving force0.00735
Rich-end driving force0.02896

Calculation inputs

Live updates

Hydraulic basis
kg/h
kg/h
kg/m³
kg/m³
mPa·s
Packing and shell
m⁻¹
%
m
0 uses the target size
Linear-equilibrium absorption

Use solute-free mole ratios for the transfer-height calculation.

Converts mass flow to molar flow ratio
m
Back to results

Equations and assumptions

Flow parameter
FLV = (L/G)√(ρV/ρL)
Modern flood curve
ΔPfl = 0.115 Fp^0.7 · CP = Csf √Fp ν^0.05
Terminal driving force
Δrich = Δlean + (1 − 1/A)(yin − yout)
Packed height
Z = HTUOG · ln(Δrich/Δlean)/(1 − 1/A)

The Strigle choice evaluates the fitted random-packing GPDC at the Kister–Gill incipient-flood pressure drop in in H₂O/ft. The chart fit uses base-10 log FLV, kinematic liquid viscosity in cSt, and packing factor in ft⁻¹. The legacy Eckert option uses a direct flood-curve fit in natural log FLV with μL in Pa·s and Fp in ft⁻¹.

Prefilled packing factors are representative screening values. Structured packing uses the generalized curve with an explicit review flag. Use measured or vendor capacity data for that packing geometry, particularly above FLV of 0.3.

The Kremser-style transfer integral assumes constant solute-free molar flow and linear equilibrium. At A = 1 it becomes (yin − yout)/Δlean. For positive removal, both terminal driving forces must be positive.

Method references