DistillColumnLab
Menu

Worked example · Packed beds

Structured packing hydraulic screen

Estimate GPDC flood capacity, then convert overall gas transfer units into packed height.

Estimate a diameter for a representative structured packing at a 68% flood target.

Required ID
0.9378 m
% flood
68 %
Gas NTU
3.177
Bed height
1.588 m

GPDC capacity curve and packed bed

Live schematic
GPDC capacity curve with a packed bed cross-section0.010.0320.10.32100.0410.0820.120.16C-FACTOR m/sFLOW PARAMETER Fₗᵥ1.59 mFlood curveTarget loadOperating point
Check packing-specific data

This point uses a generalized curve. Structured packing and operation outside the usual fit window need measured capacity data.

Superficial gas velocity ÷ predicted flood68 %
Review marker 80 % Screen limit 100 %

Worked solution

  1. Locate the hydraulic duty

    The liquid and gas mass flows give FLV = 0.0729. The selected correlation gives Cf = 0.1135 m/s and Uf = 2.45 m/s.

  2. Size area for the target fraction

    At 68 % of flood the required shell is 0.9378 m. The checked shell runs at 68 % of the predicted limit.

  3. Integrate the driving force

    A = 1.789 gives terminal forces of 0.00735 and 0.02985. The integral gives 3.177 transfer units, which at 0.5 m per unit requires 1.588 m of packing.

The structured preset uses the generalized curve for screening and requires packing-specific data. The derivation uses SI units.

Calculation details
Flow parameter FLV0.0729
Flooding C-factor0.1135 m/s
Flood velocity2.45 m/s
Operating superficial velocity1.666 m/s
Checked shell ID0.9378 m
Operating gas flow4,143 Am³/h
Kister–Gill flood gradient (reference)625.6 Pa/m
Absorption factor A1.789
Lean-end driving force0.00735
Rich-end driving force0.02985

Calculation inputs

Live updates

Hydraulic basis
kg/h
kg/h
kg/m³
kg/m³
mPa·s
Packing and shell
m⁻¹
%
m
0 uses the target size
Linear-equilibrium absorption

Use solute-free mole ratios for the transfer-height calculation.

Converts mass flow to molar flow ratio
m
Back to results

Equations and assumptions

Flow parameter
FLV = (L/G)√(ρV/ρL)
Modern flood curve
ΔPfl = 0.115 Fp^0.7 · CP = Csf √Fp ν^0.05
Terminal driving force
Δrich = Δlean + (1 − 1/A)(yin − yout)
Packed height
Z = HTUOG · ln(Δrich/Δlean)/(1 − 1/A)

The Strigle choice evaluates the fitted random-packing GPDC at the Kister–Gill incipient-flood pressure drop in in H₂O/ft. The chart fit uses base-10 log FLV, kinematic liquid viscosity in cSt, and packing factor in ft⁻¹. The legacy Eckert option uses a direct flood-curve fit in natural log FLV with μL in Pa·s and Fp in ft⁻¹.

Prefilled packing factors are representative screening values. Structured packing uses the generalized curve with an explicit review flag. Use measured or vendor capacity data for that packing geometry, particularly above FLV of 0.3.

The Kremser-style transfer integral assumes constant solute-free molar flow and linear equilibrium. At A = 1 it becomes (yin − yout)/Δlean. For positive removal, both terminal driving forces must be positive.

Method references