Legacy Eckert ceramic-ring flood

Estimate GPDC flood capacity, then convert overall gas transfer units into packed height.

Use a 25 mm ceramic Raschig ring preset with 1,500 kg/h of liquid and 568 kg/h of gas.

Required ID
0.4275 m
% flood
70 %
Gas NTU
3.673
Bed height
2.388 m

GPDC capacity curve and packed bed

Live schematic
GPDC capacity curve with a packed bed cross-section0.010.0320.10.32100.0170.0350.0520.069C-FACTOR m/sFLOW PARAMETER Fₗᵥ2.39 mFlood curveTarget loadOperating point
Below flood screening band

Velocity is below the screening threshold at the entered load.

Superficial gas velocity ÷ predicted flood70 %
Review marker 80 % Screen limit 100 %

Worked solution

  1. Locate the hydraulic duty

    The liquid and gas mass flows give FLV = 0.09075. The selected correlation gives Cf = 0.04571 m/s and Uf = 1.329 m/s.

  2. Size area for the target fraction

    At 70 % of flood the required shell is 0.4275 m. The checked shell runs at 70 % of the predicted limit.

  3. Integrate the driving force

    A = 1.761 gives terminal forces of 0.005 and 0.02444. The integral gives 3.673 transfer units, which at 0.65 m per unit requires 2.388 m of packing.

This high packing-factor preset uses the direct Eckert flood curve. The derivation uses SI units.

Calculation details
Flow parameter FLV0.09075
Flooding C-factor0.04571 m/s
Flood velocity1.329 m/s
Operating superficial velocity0.9306 m/s
Checked shell ID0.4275 m
Operating gas flow480.9 Am³/h
Kister–Gill flood gradient (reference)3,548 Pa/m
Absorption factor A1.761
Lean-end driving force0.005
Rich-end driving force0.02444

Calculation inputs

Live updates

Hydraulic basis
kg/h
kg/h
kg/m³
kg/m³
mPa·s
Packing and shell
m⁻¹
%
m
0 uses the target size
Linear-equilibrium absorption

Use solute-free mole ratios for the transfer-height calculation.

Converts mass flow to molar flow ratio
m
Back to results

Equations and assumptions

Flow parameter
FLV = (L/G)√(ρV/ρL)
Modern flood curve
ΔPfl = 0.115 Fp^0.7 · CP = Csf √Fp ν^0.05
Terminal driving force
Δrich = Δlean + (1 − 1/A)(yin − yout)
Packed height
Z = HTUOG · ln(Δrich/Δlean)/(1 − 1/A)

The Strigle choice evaluates the fitted random-packing GPDC at the Kister–Gill incipient-flood pressure drop in in H₂O/ft. The chart fit uses base-10 log FLV, kinematic liquid viscosity in cSt, and packing factor in ft⁻¹. The legacy Eckert option uses a direct flood-curve fit in natural log FLV with μL in Pa·s and Fp in ft⁻¹.

Prefilled packing factors are representative screening values. Structured packing uses the generalized curve with an explicit review flag. Use measured or vendor capacity data for that packing geometry, particularly above FLV of 0.3.

The Kremser-style transfer integral assumes constant solute-free molar flow and linear equilibrium. At A = 1 it becomes (yin − yout)/Δlean. For positive removal, both terminal driving forces must be positive.

Method references