DistillColumnLab
Menu

Worked example · Gas–solid separation

Stairmand high-efficiency cut size

Estimate d₅₀, target-particle capture, pressure drop and inlet velocity for a tangential gas cyclone.

Estimate 12 µm grade collection for a 650 mm Stairmand high-efficiency cyclone.

Cut size d₅₀
3.93 µm
Grade capture
90.31 %
Inlet speed
17.75 m/s
Pressure drop
1.19 kPa

Cyclone vortex and grade-efficiency curve

Live schematic
Tangential cyclone flow and Lapple grade-efficiency curve04.989.9614.90%50%100%TANGENTIAL INLET17.8 m/sGRADE EFFICIENCYPARTICLE SIZE µmOuter vortexGrade curveTarget particle
Within inlet velocity band

The inlet velocity falls within the 10–20 m/s screening band.

Tangential inlet velocity17.8 m/s
Review marker 20 m/s Screen limit 25 m/s

Worked solution

  1. Find the inlet velocity

    At an inlet area of 0.04225 m², the actual gas flow gives vi = 17.75 m/s.

  2. Calculate the grade point

    Lapple gives a 50% cut of 3.93 µm. At 12 µm, the fractional capture is 90.31 %.

  3. Evaluate static pressure loss

    The geometry gives 6.4 velocity heads. Multiplying by ½ρg vi² yields 1.19 kPa.

The target particle lies relative to the 50% cut on the grade curve. The derivation uses SI units.

Calculation details
Shepherd–Lapple velocity heads NH6.4
Tangential inlet area0.04225 m²
Inlet height325 mm
Inlet width130 mm
Vortex finder bore325 mm
Overall body height2.6 m

Calculation inputs

Live updates

Gas and solids
Am³/h
kg/m³
mPa·s
kg/m³
µm
Cyclone geometry

Editing a proportion switches the preset to Custom.

m
Back to results

Equations and assumptions

Inlet velocity
vi = Qg/(a · b)
Cut diameter
d₅₀ = √[9 μ b / (2π Ne vi (ρp − ρg))]
Fractional capture
η = 1/[1 + (d₅₀/dp)²]
Pressure drop
ΔP = 0.5 ρg vi² NH · NH = 16 a b/De²

Preset dimensions are published standard proportions. The pressure-drop coefficient is the Shepherd–Lapple estimate for a standard tangential inlet. Effective turns are an explicit Lapple model input.

The grade curve predicts collection at one particle diameter. Overall mass efficiency additionally requires a particle-size distribution. The meter marks a 20 m/s screening ceiling, with an additional high-velocity flag above 25 m/s.

Method references