Worked example · Packed beds
Structured packing hydraulic screen
Estimate GPDC flood capacity, then convert overall gas transfer units into packed height.
Estimate a diameter for a representative structured packing at a 68% flood target.
- Required ID
- 0.9378 m
- % flood
- 68 %
- Gas NTU
- 3.177
- Bed height
- 1.588 m
GPDC capacity curve and packed bed
Live schematicThis point uses a generalized curve. Structured packing and operation outside the usual fit window need measured capacity data.
Calculation inputs
- Liquid mass flow L
- 13,700 kg/h
- Gas mass flow G
- 8,700 kg/h
- Liquid density ρL
- 980 kg/m³
- Gas density ρV
- 2.1 kg/m³
- Liquid viscosity μL
- 1.05 mPa·s
- Packing preset
- Structured screening preset
- Packing factor Fp
- 49.21 m⁻¹
- Flood correlation
- Strigle / Kister–Gill GPDC
- Design flood target
- 68 %
- Check shell ID
- 0 m
- Equilibrium slope m
- 1.1
- Carrier MW ratio MG/ML
- 1.25
- Inlet gas solute ratio yin
- 0.06
- Outlet gas solute ratio yout
- 0.009
- Inlet liquid solute ratio xin
- 0.0015
- Overall gas HTU
- 0.5 m
Worked solution
- Locate the hydraulic duty
The liquid and gas mass flows give FLV = 0.0729. The selected correlation gives Cf = 0.1135 m/s and Uf = 2.45 m/s.
- Size area for the target fraction
At 68 % of flood the required shell is 0.9378 m. The checked shell runs at 68 % of the predicted limit.
- Integrate the driving force
A = 1.789 gives terminal forces of 0.00735 and 0.02985. The integral gives 3.177 transfer units, which at 0.5 m per unit requires 1.588 m of packing.
The structured preset uses the generalized curve for screening and requires packing-specific data. The derivation uses SI units.
| Flow parameter FLV | 0.0729 |
|---|---|
| Flooding C-factor | 0.1135 m/s |
| Flood velocity | 2.45 m/s |
| Operating superficial velocity | 1.666 m/s |
| Checked shell ID | 0.9378 m |
| Operating gas flow | 4,143 Am³/h |
| Kister–Gill flood gradient (reference) | 625.6 Pa/m |
| Absorption factor A | 1.789 |
| Lean-end driving force | 0.00735 |
| Rich-end driving force | 0.02985 |
Calculation inputs
Live updates
Equations and assumptions
- Flow parameter
- FLV = (L/G)√(ρV/ρL)
- Modern flood curve
- ΔPfl = 0.115 Fp^0.7 · CP = Csf √Fp ν^0.05
- Terminal driving force
- Δrich = Δlean + (1 − 1/A)(yin − yout)
- Packed height
- Z = HTUOG · ln(Δrich/Δlean)/(1 − 1/A)
The Strigle choice evaluates the fitted random-packing GPDC at the Kister–Gill incipient-flood pressure drop in in H₂O/ft. The chart fit uses base-10 log FLV, kinematic liquid viscosity in cSt, and packing factor in ft⁻¹. The legacy Eckert option uses a direct flood-curve fit in natural log FLV with μL in Pa·s and Fp in ft⁻¹.
Prefilled packing factors are representative screening values. Structured packing uses the generalized curve with an explicit review flag. Use measured or vendor capacity data for that packing geometry, particularly above FLV of 0.3.
The Kremser-style transfer integral assumes constant solute-free molar flow and linear equilibrium. At A = 1 it becomes (yin − yout)/Δlean. For positive removal, both terminal driving forces must be positive.