Engineering reference
Calculation methodology
Use these models for preliminary sizing and sensitivity checks. Detailed equipment selection requires service data, hardware information and engineering review.
Units and assumptions
The calculations store a consistent metric basis. Toggling display units preserves the physical inputs. All EOS pressures are absolute. The actual and reference volume flows carry the same mass.
Share links carry scenario changes in the URL query. The link uses the address of the current page. Open index.html directly for offline use.
Binary distillation shortcut
The model uses constant relative volatility, constant molar overflow, a total condenser and one equilibrium reboiler. The theoretical total includes the reboiler. The actual tray count applies efficiency after subtracting that reboiler.
Gilliland uses the Molokanov exponential fit. Kirkbride estimates the section split and the feed tray is rounded from the top of the column. The McCabe–Thiele staircase uses the two material-balance operating lines at the entered reflux and may give a different stage count.
q below 0 represents superheated vapor and q above 1 represents subcooled liquid. The reflux multiplier requires positive minimum reflux and positive internal stripping flows.
Trayed-column flooding
The Lygeros–Magoulas fit to Fair data uses tray spacing in meters and the reference surface tension of 20 mN/m. Apply the system factor to account for foaming or service derating.
The meter marks 80% of predicted jet flood. The 80–85% operating band is a screening range. Downcomer area is reserved in the net-area calculation. Detailed backup, froth height, weeping and entrainment need tray hardware data.
Packed-column diameter and height
The Strigle choice evaluates the fitted random-packing GPDC at the Kister–Gill incipient-flood pressure drop in in H₂O/ft. The chart fit uses base-10 log FLV, kinematic liquid viscosity in cSt, and packing factor in ft⁻¹. The legacy Eckert option uses a direct flood-curve fit in natural log FLV with μL in Pa·s and Fp in ft⁻¹.
Prefilled packing factors are representative screening values. Structured packing uses the generalized curve with an explicit review flag. Use measured or vendor capacity data for that packing geometry, particularly above FLV of 0.3.
The Kremser-style transfer integral assumes constant solute-free molar flow and linear equilibrium. At A = 1 it becomes (yin − yout)/Δlean. For positive removal, both terminal driving forces must be positive.
Isothermal flash and drum sizing
K-values are supplied at the flash temperature and pressure. The material balance uses the component molecular weights to convert mole split to phase mass flow. Compositions are reported only for phases that exist at the entered conditions.
The minimum shell ID is the larger of the gas area at the chosen design fraction of Souders–Brown velocity and the ID that stores liquid surge within a depth of one diameter. The sketch reserves two diameters above surge depth for gas disengagement and demister space.
CSTR and PFR reactor sizing
The ideal model is steady state, isothermal and constant density. It assumes one irreversible power-law reaction and no change in volumetric flow. Enter a rate constant with units for the selected order.
The cascade check divides the PFR volume among equal CSTRs. A separate cascade sizing step computes the volume needed at the target. For second order each tank solves Ci + kτtank Ci² = Ci−1 using a cancellation-safe positive root.
Gravity decanter and API separator
The circular decanter uses the interfacial chord in the separation area and a circular segment for continuous-phase hold-up. The rectangular bay sizes for corrected overflow area, residence time and a bulk horizontal velocity at most the lesser of 15 vt and 3 ft/min.
The API-style sizing includes an interpolated turbulence and short-circuit factor at the allowed velocity. It checks representative geometry criteria for oil rising in water. The Stokes model assumes dilute spherical droplets and is screened at Rep ≤ 1.
The seal-leg crest is measured from the vessel bottom at equal gas pressure on the two sides. Dynamic head losses, nozzle allowances and emulsions require separate evaluation.
Cyclone cut size and pressure drop
Preset dimensions are published standard proportions. The pressure-drop coefficient is the Shepherd–Lapple estimate for a standard tangential inlet. Effective turns are an explicit Lapple model input.
The grade curve predicts collection at one particle diameter. Overall mass efficiency additionally requires a particle-size distribution. The meter marks a 20 m/s screening ceiling, with an additional high-velocity flag above 25 m/s.
Real-gas Z factor and flow
A scaled Cardano solver with Newton refinement returns the largest real admissible root Z > B. The subcritical flag requests a phase-stability check. The gas preset is a pure-fluid or pseudo-pure approximation without mixing rules.
The reference state defaults to 0 °C and 101.325 kPa absolute. Nm³/h and SCFM labels both use the entered reference temperature and absolute pressure, so toggling units preserves the reference condition. Set the reference state required by your metering convention.