Rachford–Rice · Souders–Brown
Isothermal flash and drum sizing
Solve a four-component vapor–liquid split and size a vertical drum from gas load and liquid surge.
- Vapor V/F
- 62.66 %
- Drum ID
- 0.6956 m
- T/T height
- 2.087 m
- Mass error
- 0 %
Vertical flash drum and mist eliminator
Live schematic
Two phase
Screen against the gas velocity limit and a liquid surge depth of one shell diameter.
Highest gas velocity or surge-depth approach100 %
Review marker 85 %
Screen limit 100 %
Calculation inputs
- z1 feed
- 0.52
- K1
- 2.4
- MW1
- 44.1 kg/kmol
- z2 feed
- 0.33
- K2
- 0.62
- MW2
- 58.12 kg/kmol
- z3 feed
- 0.15
- K3
- 0.23
- MW3
- 72.15 kg/kmol
- z4 feed
- 0
- K4
- 0.1
- MW4
- 86.18 kg/kmol
- Feed basis
- Mass flow
- Feed mass flow F
- 5,400 kg/h
- Liquid density ρL
- 700 kg/m³
- Vapor density ρV
- 6.2 kg/m³
- Demister K-factor
- 0.105 m/s
- Gas design fraction
- 80 %
- Liquid surge time
- 5 min
- Check shell ID
- 0 m
| Component | Feed z | Liquid x | Vapor y |
|---|---|---|---|
| 1 | 0.52 | 0.27699 | 0.66478 |
| 2 | 0.33 | 0.43314 | 0.26855 |
| 3 | 0.15 | 0.28986 | 0.066669 |
| 4 | 0 | 0 | 0 |
| Phase state | Two phase |
|---|---|
| Mixed feed molecular weight | 52.93 kg/kmol |
| Feed molar flow | 102 kmol/h |
| Feed mass flow | 5,400 kg/h |
| Vapor mass flow | 3,179 kg/h |
| Liquid mass flow | 2,221 kg/h |
| Actual vapor flow | 512.8 Am³/h |
| Liquid flow | 3.172 m³/h |
| Gas velocity limit | 1.111 m/s |
| Liquid surge volume | 0.2644 m³ |
| Required drum ID | 0.6956 m |
| Liquid surge depth | 0.6956 m |
| Gas velocity approach | 33.74 % |
| Surge-depth approach | 100 % |
Calculation inputs
Live updates
Equations and assumptions
- Phase endpoints
- Σ zᵢKᵢ ≤ 1 → liquid · Σ zᵢ/Kᵢ ≤ 1 → vapor
- Two-phase split
- Σ zᵢ(Kᵢ − 1) / [1 + β(Kᵢ − 1)] = 0
- Composition
- xᵢ = zᵢ/[1 + β(Kᵢ − 1)] · yᵢ = Kᵢxᵢ
- Drum height
- HT/T = 2D + Vsurge / (πD²/4)
K-values are supplied at the flash temperature and pressure. The material balance uses the component molecular weights to convert mole split to phase mass flow. Compositions are reported only for phases that exist at the entered conditions.
The minimum shell ID is the larger of the gas area at the chosen design fraction of Souders–Brown velocity and the ID that stores liquid surge within a depth of one diameter. The sketch reserves two diameters above surge depth for gas disengagement and demister space.