DistillColumnLab
Menu

Peng–Robinson · Redlich–Kwong

Real-gas Z factor and flow

Solve Peng–Robinson or Redlich–Kwong for density and convert standard to actual gas volume at equal mass flow.

Z factor
0.90227
Gas density
36.68 kg/m³
Actual flow
19.57 Am³/h
Standard flow
1,000 Nm³/h

Vapor-branch compressibility isotherm

Live schematic
Compressibility versus absolute pressure along the selected isotherm01,5603,1204,6806,2400.87420.90860.94310.97751.012COMPRESSIBILITY ZPRESSURE kPa absISOTHERM30 °COPERATING Z0.90227ADMISSIBLE ROOTS1EOS vapor rootIdeal gasOperating point
Real-gas correction material

The 5% deviation marker compares the operating compressibility to Z = 1.

Absolute compressibility departure |Z − 1|9.77 %
Review marker 5 % Screen limit 10 %

Calculation details
Mass flow717.9 kg/h
Reference compressibility0.997025
Reference density0.7179 kg/m³
Operating reduced temperature1.591
Operating reduced pressure1.131
Operating EOS coefficient A0.1646
Operating EOS coefficient B0.05529
Scaled cubic residual1.791e-17

Admissible roots 0.9022685

Calculation inputs

Live updates

Gas and equation
kg/kmol
°C
bar abs
Operating and reference states
°C
kPa abs
°C
kPa abs
Volume flow

Both unit systems use the reference state shown above.

Nm³/h
Back to results

Equations and assumptions

Peng–Robinson cubic
Z³ − (1−B)Z² + (A−2B−3B²)Z − (AB−B²−B³) = 0
Redlich–Kwong cubic
Z³ − Z² + (A−B−B²)Z − AB = 0
Gas density
ρ = P MW / (Z R T)
Volume conversion
Qs ρs = Qa ρa

A scaled Cardano solver with Newton refinement returns the largest real admissible root Z > B. The subcritical flag requests a phase-stability check. The gas preset is a pure-fluid or pseudo-pure approximation without mixing rules.

The reference state defaults to 0 °C and 101.325 kPa absolute. Nm³/h and SCFM labels both use the entered reference temperature and absolute pressure, so toggling units preserves the reference condition. Set the reference state required by your metering convention.

Method references