One Net Inch on a 120-Acre LEPA Pivot

Estimate gross water, runtime and seasonal acre-feet for a 120-acre LEPA pivot served by an 800 US gpm measured well.

Pump runtime for this event 79.87 h
All results

Worksheet inputs

Event & delivery system
Peak day & season
Use net crop demand after effective rain if appropriate.

Planning estimate

Pump runtime for this event
79.87 h
Net water reaching crop
3,258,514.3 US gal
Gross water to pump
3,833,546.3 US gal
Gross application depth
1.176 in
Estimated application losses
575,031.9 US gal
Flow per area for peak ET
5.55 gpm/ac
Total flow needed for peak ET
665.5 US gpm
Pumping time per peak day
19.97 h/day
Seasonal gross volume
141.176 ac-ft
Net depth, system losses & pump time
Net depth, system losses & pump timeWater depth1 in net1.18 in grossEvent pumping time79.87 h24 h/day availableNet waterApplication losses

Field note

Use the pump or flow meter’s measured delivery at operating pressure. Check field uniformity and keep seasonal pumping records for allocation planning.

Questions from the field

How many gross inches supply one net inch at 85%?

Divide one inch by 0.85 to get approximately 1.176 inches of gross application.

How should I account for a part-circle pivot?

Enter the area actually irrigated. Exclude untreated corners or other places outside the watered arc.