A Low-Flow Well against Peak-Day Demand
Check whether a 310 US gpm well can maintain peak ET on 96 acres with 16 available pumping hours and 83% efficiency.
Planning estimate
Measured flow is below the peak ET target for the available pumping window.
- Pump runtime for this event
- 126.64 h
- Net water reaching crop
- 1,955,108.6 US gal
- Gross water to pump
- 2,355,552.5 US gal
- Gross application depth
- 0.904 in
- Estimated application losses
- 400,443.9 US gal
- Flow per area for peak ET
- 11.59 gpm/ac
- Total flow needed for peak ET
- 1,112.3 US gpm
- Pumping time per peak day
- 57.41 h/day
- Seasonal gross volume
- 86.747 ac-ft
Field note
A peak-day shortfall can guide acreage or scheduling decisions. Consider soil water reserves, local scheduling guidance and the difference between well rating and measured output.
Questions from the field
What does the low-flow warning compare?
It compares entered measured flow with the calculated peak flow needed to replace net ET within the available daily hours.
Can a well below peak demand still complete a single event?
It may, if allowed enough pumping time. Crop stress risk depends on the longer water balance and available soil water.