Measured Nozzle Catch on a 90-Foot Boom

Turn a 46 fluid ounce one-minute nozzle catch at 7.2 mph into gallons per acre, tank coverage and measured output for a 90-foot boom.

Flow per nozzle 0.3594 US gpm
All results

Worksheet inputs

Nozzle & carrier calibration
Tank & field
Copy the liquid product rate from the label. Zero gives a water-only check.

Planning estimate

Flow per nozzle
0.3594 US gpm
Carrier application rate
19.77 GPA
Area per full tank
40.47 ac
Product per full tank
0 fl oz
Carrier in final partial tank
712.58 US gal
Product for final partial tank
0 fl oz
Area left for partial tank
36.05 ac
Full tanks for this field
2
Approximate nozzles across swath
72 nozzles
Estimated total boom flow
25.88 US gpm
Rate at 20% faster and fixed pressure
16.47 GPA
Pressure at 20% faster for same rate
60.5 psi
Boom spacing & speed response
Boom spacing & speed responseOperating swath15 in nozzle centers72 tips estimatedGPA at fixed pressure5 mph9.4 mphCurrent rate 19.8 GPA · 20% faster 16.5 GPA

Field note

Average the output of sound tips after measuring across boom sections. Clean or replace tips that do not match manufacturer or extension tolerances before calculating the mean.

Questions from the field

Should I multiply a one-minute catch by the nozzle count?

Enter the catch from one representative nozzle. The worksheet estimates total boom flow separately using the operating width and spacing.

How can I convert a 30-second catch to this input?

Double the volume of a steady 30-second catch to get the equivalent one-minute volume.