40-channel EDFA headroom check

Forty equal-power lines at −3 dBm use a 20 dBm composite output limit.

Inputs

Edit any power unit to update the other two. Select aggregate RX only when the receiver’s limits apply to the entire optical band.

Optical power and channels
Power per channel
dBm
Receiver and attenuation
dB
dBm
dBm
LIVE ANATOMY

Receiver dynamic range

Receiver dynamic rangeCOMPOSITE13.021dBmRX INPUT-5dBmCENTER ATTEN10dBEDFA ROOM6.979dBInput -5 dBmAfter pad -15 dBmRX floor-23 dBmMidpoint-15 dBmRX ceiling-7 dBmRECEIVER WINDOWRX floorRX ceiling-5 dBm input
Attenuator neededReceived power exceeds the ceiling. Check the minimum and midpoint attenuation.

Composite power is at or above +10 dBm. Review the accessible optical power and marked laser class.

Power and amplifier

Per-channel optical power
-3 dBm
Per-channel linear power
0.501187 mW
Per-channel linear power
501.187234 µW
Composite optical power
13.021 dBm
Composite linear power
20.047489 mW
EDFA headroom
6.979 dB

Receiver and attenuator

RX before attenuation
-5 dBm
Window midpoint
-15 dBm
Minimum to clear overload
2 dB
Attenuation to midpoint
10 dB
Maximum before sensitivity
18 dB
RX after calculated attenuation
-15 dBm

What to check

Add channel power in mW before converting the composite back to dBm.

Open the general optical power converter calculator

Formulas and assumptions

Power conversion

P(mW) = 10^(dBm / 10); dBm = 10 log₁₀(PmW); P(µW) = 1000 × P(mW)

Enter positive linear power. Equal-power WDM channels sum in linear units.

Composite power and EDFA headroom

Ptotal(dBm) = Pchannel + 10 log₁₀(N); headroom = EDFA limit − Ptotal

Use a per-channel level at the EDFA output plane for this comparison. Check the manufacturer’s gain, ASE, channel loading and saturation limits.

Inline attenuation

RXtarget = (sensitivity + overload ceiling) / 2; Acenter = max(0, RX − RXtarget)

The midpoint in dBm leaves equal dB headroom on either side. An attenuator can lower power only. Use the correct receiver plane and rated component.

Laser class comes from the equipment marking and applicable accessible emission limits. A separate +10 dBm composite advisory highlights elevated optical power for review. IEC Class 1M and Class 3B handling depends on the marked class and accessible emission conditions.

Worked examples

Open a scenario and edit any parameter.