Receive power below the midpoint

An in-range receiver sits below the center of its power window.

Inputs

Edit any power unit to update the other two. Select aggregate RX only when the receiver’s limits apply to the entire optical band.

Optical power and channels
Power per channel
dBm
Receiver and attenuation
dB
dBm
dBm
LIVE ANATOMY

Receiver dynamic range

Receiver dynamic rangeCOMPOSITE-2.969dBmRX INPUT-18dBmCENTER ATTEN0dBEDFA ROOM22.969dBInput -18 dBmAfter pad -18 dBmRX floor-23 dBmMidpoint-15 dBmRX ceiling-7 dBmRECEIVER WINDOWRX floorRX ceiling-18 dBm input
Within RX windowReceived power lies within the entered receiver window.

The current receive level is below the midpoint. A passive attenuator cannot reach that higher target.

Power and amplifier

Per-channel optical power
-12 dBm
Per-channel linear power
0.063096 mW
Per-channel linear power
63.095734 µW
Composite optical power
-2.969 dBm
Composite linear power
0.504766 mW
EDFA headroom
22.969 dB

Receiver and attenuator

RX before attenuation
-18 dBm
Window midpoint
-15 dBm
Minimum to clear overload
0 dB
Attenuation to midpoint
0 dB
Maximum before sensitivity
5 dB
RX after calculated attenuation
-18 dBm

What to check

The target is above the received power. The maximum attenuation before sensitivity remains positive.

Open the general optical power converter calculator

Formulas and assumptions

Power conversion

P(mW) = 10^(dBm / 10); dBm = 10 log₁₀(PmW); P(µW) = 1000 × P(mW)

Enter positive linear power. Equal-power WDM channels sum in linear units.

Composite power and EDFA headroom

Ptotal(dBm) = Pchannel + 10 log₁₀(N); headroom = EDFA limit − Ptotal

Use a per-channel level at the EDFA output plane for this comparison. Check the manufacturer’s gain, ASE, channel loading and saturation limits.

Inline attenuation

RXtarget = (sensitivity + overload ceiling) / 2; Acenter = max(0, RX − RXtarget)

The midpoint in dBm leaves equal dB headroom on either side. An attenuator can lower power only. Use the correct receiver plane and rated component.

Laser class comes from the equipment marking and applicable accessible emission limits. A separate +10 dBm composite advisory highlights elevated optical power for review. IEC Class 1M and Class 3B handling depends on the marked class and accessible emission conditions.

Worked examples

Open a scenario and edit any parameter.