−30 dBm and one microwatt

A one-channel receiver test with weak launch and 4 dB of plant loss.

Inputs

Edit any power unit to update the other two. Select aggregate RX only when the receiver’s limits apply to the entire optical band.

Optical power and channels
Power per channel
dBm
Receiver and attenuation
dB
dBm
dBm
LIVE ANATOMY

Receiver dynamic range

Receiver dynamic rangeCOMPOSITE-30dBmRX INPUT-34dBmCENTER ATTEN0dBEDFA ROOM50dBInput -34 dBmAfter pad -34 dBmRX floor-32 dBmMidpoint-19.5 dBmRX ceiling-7 dBmRECEIVER WINDOWRX floorRX ceiling-34 dBm input
Below sensitivityAdding passive attenuation would deepen the receive-power shortfall.

The current receive level is below the midpoint. A passive attenuator cannot reach that higher target.

Power and amplifier

Per-channel optical power
-30 dBm
Per-channel linear power
0.001 mW
Per-channel linear power
1 µW
Composite optical power
-30 dBm
Composite linear power
0.001 mW
EDFA headroom
50 dB

Receiver and attenuator

RX before attenuation
-34 dBm
Window midpoint
-19.5 dBm
Minimum to clear overload
0 dB
Attenuation to midpoint
0 dB
Maximum before sensitivity
0 dB
RX after calculated attenuation
-34 dBm

What to check

A passive attenuator cannot raise the receive level above sensitivity.

Open the general optical power converter calculator

Formulas and assumptions

Power conversion

P(mW) = 10^(dBm / 10); dBm = 10 log₁₀(PmW); P(µW) = 1000 × P(mW)

Enter positive linear power. Equal-power WDM channels sum in linear units.

Composite power and EDFA headroom

Ptotal(dBm) = Pchannel + 10 log₁₀(N); headroom = EDFA limit − Ptotal

Use a per-channel level at the EDFA output plane for this comparison. Check the manufacturer’s gain, ASE, channel loading and saturation limits.

Inline attenuation

RXtarget = (sensitivity + overload ceiling) / 2; Acenter = max(0, RX − RXtarget)

The midpoint in dBm leaves equal dB headroom on either side. An attenuator can lower power only. Use the correct receiver plane and rated component.

Laser class comes from the equipment marking and applicable accessible emission limits. A separate +10 dBm composite advisory highlights elevated optical power for review. IEC Class 1M and Class 3B handling depends on the marked class and accessible emission conditions.

Worked examples