0 dBm and one milliwatt

Start with a single 0 dBm channel. Edit its mW or µW value to see the inverse conversion.

Inputs

Edit any power unit to update the other two. Select aggregate RX only when the receiver’s limits apply to the entire optical band.

Optical power and channels
Power per channel
dBm
Receiver and attenuation
dB
dBm
dBm
LIVE ANATOMY

Receiver dynamic range

Receiver dynamic rangeCOMPOSITE0dBmRX INPUT-12dBmCENTER ATTEN3dBEDFA ROOM20dBInput -12 dBmAfter pad -15 dBmRX floor-23 dBmMidpoint-15 dBmRX ceiling-7 dBmRECEIVER WINDOWRX floorRX ceiling-12 dBm input
Within RX windowReceived power lies within the entered receiver window.

Power and amplifier

Per-channel optical power
0 dBm
Per-channel linear power
1 mW
Per-channel linear power
1,000 µW
Composite optical power
0 dBm
Composite linear power
1 mW
EDFA headroom
20 dB

Receiver and attenuator

RX before attenuation
-12 dBm
Window midpoint
-15 dBm
Minimum to clear overload
0 dB
Attenuation to midpoint
3 dB
Maximum before sensitivity
11 dB
RX after calculated attenuation
-15 dBm

What to check

0 dBm corresponds to 1 mW or 1,000 µW.

Open the general optical power converter calculator

Formulas and assumptions

Power conversion

P(mW) = 10^(dBm / 10); dBm = 10 log₁₀(PmW); P(µW) = 1000 × P(mW)

Enter positive linear power. Equal-power WDM channels sum in linear units.

Composite power and EDFA headroom

Ptotal(dBm) = Pchannel + 10 log₁₀(N); headroom = EDFA limit − Ptotal

Use a per-channel level at the EDFA output plane for this comparison. Check the manufacturer’s gain, ASE, channel loading and saturation limits.

Inline attenuation

RXtarget = (sensitivity + overload ceiling) / 2; Acenter = max(0, RX − RXtarget)

The midpoint in dBm leaves equal dB headroom on either side. An attenuator can lower power only. Use the correct receiver plane and rated component.

Laser class comes from the equipment marking and applicable accessible emission limits. A separate +10 dBm composite advisory highlights elevated optical power for review. IEC Class 1M and Class 3B handling depends on the marked class and accessible emission conditions.

Worked examples

Open a scenario and edit any parameter.