Cellulose Bags for a 1,200 ft² Attic From R-19 to R-49
Estimate blown-in cellulose bags to add R-30 over existing R-19 insulation in a 1,200-square-foot attic.
Shopping list
44 bagsBlown-in cellulose 27.4 ft² coverage per bag at this depth
- Insulated area
- 1,200 ft²
- Added settled depth
- 8.3 in
- Cavity or attic total
- 49 R
- Effective wall assembly
- 18.44 R
Worked takeoff
Determine added thermal resistance
19 R existing + 30 R added = 49 R. At 3.61446 R/in, plan for 8.3 in added settled depth.
Round to whole packages
1,200 ft² ÷ 27.4 ft² per bag at the added depth, plus 0% reserve, gives 44 bags.
Check the parallel wall paths
1 ÷ ((1 − 23%) ÷ 50.5 R cavity path + 23% ÷ 5.9 R framing path) = 18.44 R.
Check before you buy
This uses the Greenfiber R-30 row for the added layer, with 27.4 ft² maximum coverage per bag and an 8.3 in minimum settled thickness. Confirm the existing layer is intact and the purchased bag shows the same values.
Read the product chart for minimum installed and settled depth and minimum bags. Confirm wall or attic use, package coverage at your spacing, and the condition and depth of existing insulation.
Frequently asked questions
Why use the R-30 coverage row for a target of R-49?
The assumed existing layer supplies R-19. The added layer needs the remaining R-30 if the existing layer keeps its measured thermal performance.
Does a 44-bag order alone guarantee the attic reaches the target?
The label specifies both a minimum bag count and a minimum depth. Check depths on site and address uneven or compressed existing material.