Cellulose Bags for a 1,200 ft² Attic From R-19 to R-49

Estimate blown-in cellulose bags to add R-30 over existing R-19 insulation in a 1,200-square-foot attic.

Project inputs

Area and insulation
ft²
R
R
Product coverage
R/inLeave at 0 for the material’s planning value.
lb/ft³Leave at 0 for the material and location preset.
lbLeave at 0 for the loose-fill material preset.
ft²Enter the product chart yield to replace the density estimate.
%
Effective wall R-value check
%
R
R
View shopping list

Shopping list

44 bagsBlown-in cellulose 27.4 ft² coverage per bag at this depth

Insulated area
1,200 ft²
Added settled depth
8.3 in
Cavity or attic total
49 R
Effective wall assembly
18.44 R

Insulation section · relative layers Insulation section · relative layers Added · 8.3 inExisting · 19 R8.3 in added · 18.44 R effective wall rating
Schematic layout

Worked takeoff

  1. Determine added thermal resistance

    19 R existing + 30 R added = 49 R. At 3.61446 R/in, plan for 8.3 in added settled depth.

  2. Round to whole packages

    1,200 ft² ÷ 27.4 ft² per bag at the added depth, plus 0% reserve, gives 44 bags.

  3. Check the parallel wall paths

    1 ÷ ((1 − 23%) ÷ 50.5 R cavity path + 23% ÷ 5.9 R framing path) = 18.44 R.

Check before you buy

This uses the Greenfiber R-30 row for the added layer, with 27.4 ft² maximum coverage per bag and an 8.3 in minimum settled thickness. Confirm the existing layer is intact and the purchased bag shows the same values.

Read the product chart for minimum installed and settled depth and minimum bags. Confirm wall or attic use, package coverage at your spacing, and the condition and depth of existing insulation.

Frequently asked questions

Why use the R-30 coverage row for a target of R-49?

The assumed existing layer supplies R-19. The added layer needs the remaining R-30 if the existing layer keeps its measured thermal performance.

Does a 44-bag order alone guarantee the attic reaches the target?

The label specifies both a minimum bag count and a minimum depth. Check depths on site and address uneven or compressed existing material.