Blown Fiberglass for a Bare 900 ft² Attic at R-38

Use a product chart to estimate fiberglass bags and depth for a bare 900-square-foot attic at R-38.

Project inputs

Area and insulation
ft²
R
R
Product coverage
R/inLeave at 0 for the material’s planning value.
lb/ft³Leave at 0 for the material and location preset.
lbLeave at 0 for the loose-fill material preset.
ft²Enter the product chart yield to replace the density estimate.
%
Effective wall R-value check
%
R
R
View shopping list

Shopping list

18 bagsBlown-in fiberglass 52.6 ft² coverage per bag at this depth

Insulated area
900 ft²
Added settled depth
13.5 in
Cavity or attic total
38 R
Effective wall assembly
17.1 R

Insulation section · relative layers Insulation section · relative layers Added · 13.5 in13.5 in added · 17.1 R effective wall rating
Schematic layout

Worked takeoff

  1. Determine added thermal resistance

    0 R existing + 38 R added = 38 R. At 2.81481 R/in, plan for 13.5 in added settled depth.

  2. Round to whole packages

    900 ft² ÷ 52.6 ft² per bag at the added depth, plus 0% reserve, gives 18 bags.

  3. Check the parallel wall paths

    1 ÷ ((1 − 23%) ÷ 39.5 R cavity path + 23% ÷ 5.9 R framing path) = 17.1 R.

Check before you buy

This example takes 52.6 ft² per bag and 13.5 in depth from the Owens Corning AttiCat R-38 chart. Read the regional column and machine guidance for the location where the job will be installed.

Read the product chart for minimum installed and settled depth and minimum bags. Confirm wall or attic use, package coverage at your spacing, and the condition and depth of existing insulation.

Frequently asked questions

Why is the fiberglass estimate 18 bags for 900 square feet?

The example coverage of 52.6 ft² per bag gives 17.11 bags by area. Round the order up to 18.

Which depth should I mark before blowing fiberglass?

Use the product chart’s installed depth for the conditions at your site. This example’s entered chart uses 13.5 in for the reference row.